Skip to product information
1 of 1

Rat CXCL11/ITAC ELISA Kit

Rat CXCL11/ITAC ELISA Kit

Catalog Number: abs553608 Application: ELISA Reactivity: Rat Conjugation:
Price:
Regular price $368.25 USD
Regular price Sale price $368.25 USD
Size:
For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)
2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37℃ constant temperature box
4. Distilled water or deionized water

Sample processing and requirements:
Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.
Plasma: Collect specimens using EDTA or heparin as anticoagulants and centrifuge them at 1000×g for 15 minutes at 2-8℃ within 30 minutes of collection. The supernatant can be tested or stored at -20℃ or -80℃, but repeated freezing and thawing should be avoided.Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Preparation of standard gradient working solution: Add 1mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 3000pg/mL). Then dilute to the following concentrations: 3000pg/mL, 1500pg/mL, 750pg/mL, 375pg/mL, 187.5pg/mL, 93.75pg/mL, 46.875pg/mL, and 0pg/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 3000pg/mL standard working solution into the first EP tube and mix thoroughly to make a 1500pg/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.
Theory This kit uses a competitive enzyme-linked immunosorbent assay (ELISA). Samples, standards, biotin-labeled antibodies, and HRP enzyme conjugates are added sequentially to microwells pre-coated with the universal species Interferon inducible T-cell Chemoattractant (ITAC/CXCL11) antigen. After incubation and washing, the substrate TMB is used for color development. TMB is converted to blue under the catalysis of peroxidase (HRP) and to the final yellow under the action of acid. The depth of the color is negatively correlated with the universal species Interferon inducible T-cell Chemoattractant (ITAC/CXCL11) in the sample. The absorbance (OD value) is measured at a wavelength of 450nm using an enzyme reader to calculate the sample concentration.
Source Rat
Synonym Rat Interferon inducible T-cell ChemoattractantELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T Configuration  style="height: 10px; width: 29.98%; text-align: center;" width="29.9800%">Remarks
Pre-coated 96-well enzyme plate 8 holes×12 strips None
Standard 2 bottles
Dilution according to the instructions
Universal diluent
2×20mL
None
Concentrated biotinylated detection antibody (100×) 
120uL
Concentrated enzyme conjugate (100×)
120uL
Dilution according to the instructions
20× Wash solution
2×10mL
Dilute according to instructions
Substrate (TMB)
10mL
None
Stop solution
6mL
none
Sealing film
4 sheets
None
Instructions
1 serving
None
Background Interferon-induced T-cell chemokine (ITAC), also known as CXC kinetochoroid chemokine 11 (CXCL11) and interferon-γ-induced protein 9 (IP-9), is a protein encoded by the CXCL11 gene. CXC kinetochoroid chemokine 11 is a small cytokine belonging to the CXC chemokine family. It is highly expressed in peripheral blood leukocytes, pancreas, and liver, moderately expressed in the thymus, spleen, and lung, and at lower levels in the small intestine, placenta, and prostate. CXCL11 gene expression is strongly induced by interferon-γ and interferon-β and weakly induced by interferon-α. This chemokine affects its target cells by interacting with the cell surface chemokine receptor CXCR3, with a higher affinity than its other ligands, CXCL9 and CXCL10.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 46.88-3000pg/mL
Applications Serum, plasma, and other biological fluids

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)