Skip to product information
1 of 1

PGE1 ELISA Kit

PGE1 ELISA Kit

Catalog Number: abs554162 Application: ELISA Reactivity: Human,Mouse,Rat Conjugation:
Price:
Regular price $412.70 USD
Regular price Sale price $412.70 USD
Size:
For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification

Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample handling and requirements: The detection range of the kit is not equivalent to the concentration range of the analyte in the sample. Before the experiment, it is recommended to estimate the analyte concentration in the sample based on relevant literature and conduct preliminary experiments to determine the actual concentration in the sample. If the analyte concentration in the sample is too high or too low, dilute or concentrate the sample appropriately. If the sample type is not listed in the instructions, it is recommended to conduct a preliminary experiment to verify the validity of the test. Serum: Collect whole blood in a serum separator tube and place it at room temperature for 2 hours or at 2-8°C overnight. Then centrifuge at 1000×g for 20 minutes and remove the supernatant. Alternatively, store the supernatant at -20°C or -80°C, but avoid repeated freezing and thawing. Plasma: Collect the sample using EDTA or heparin as an anticoagulant. Within 30 minutes of collection, centrifuge at 1000×g for 15 minutes at 2-8°C. Remove the supernatant and test it. Alternatively, store the supernatant at -20°C or -80°C, but avoid repeated freezing and thawing. Tissue homogenate: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove any residual blood (lysed red blood cells in the homogenate may affect the test results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice or in a homogenizer. To further lyse tissue cells, the homogenate can be sonicated or repeatedly freeze-thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes and remove the supernatant for analysis.
Cell culture supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant and analyze it immediately, or store it at -20°C or -80°C, but avoid repeated freeze-thaw cycles.
Cell lysis buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and harvest the cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be harvested directly by centrifugation. Wash the collected cells three times with pre-chilled PBS and resuspend in 150-200 μL of PBS per 1 × 10^6 cells (protease inhibitors are recommended; if the cell count is very low, the PBS volume can be reduced appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500 × g for 10 minutes at 2-8°C, and remove the supernatant for testing.
Other biological samples: Centrifuge at 1000 × g for 20 minutes, and remove the supernatant for testing.
Sample Appearance: The sample should be clear and transparent, and any suspended matter should be removed by centrifugation.
Sample Storage: Samples collected for testing within one week can be stored at 4°C. If testing is not possible, aliquot the sample into single-use aliquots and freeze at -20°C (for testing within one month) or -80°C (for testing within six months). Avoid repeated freeze-thaw cycles. Hemolysis of the sample can affect the final test results, so hemolyzed samples are not suitable for this test. Pre-Assay Preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard. Allow to stand for 15 minutes to completely dissolve, then gently mix (concentration is 1000 pg/mL). Then dilute to the following concentrations: 1000 pg/mL, 500 pg/mL, 250 pg/mL, 125 pg/mL, 62.5 pg/mL, 31.25 pg/mL, 15.625 pg/mL, and 0 pg/mL. Serial dilution method: Take seven EP tubes and add 500 μL of universal diluent to each. Pipette 500 μL of the 1000 pg/mL standard working solution into the first EP tube and mix thoroughly to make a 500 pg/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of Biotin-Antibody Working Solution: 15 minutes before use, centrifuge 100 μL concentrated Biotin-Antibody at 1000 × g for 1 minute. Dilute the 100 μL concentrated Biotin-Antibody to a 1 × working concentration with universal diluent (e.g., 10 μL concentrated solution + 990 μL universal diluent). Prepare and use immediately. 4. Preparation of Enzyme Conjugate Working Solution: 15 minutes before use, centrifuge 100 μL of concentrated enzyme conjugate at 1000 × g for 1 minute. Dilute the 100 μL concentrated enzyme conjugate to a 1 × working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Preparation of 1 × Wash Solution: Add 10 mL of 20 × Wash Solution to 190 mL of distilled water. (Concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing.) Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return them to 4°C. 2. Sample Addition: Add 50 μL of sample or standard of varying concentrations to the corresponding wells. Add 50 μL of universal diluent to the blank wells, followed by 50 μL of Biotin-Antibody Working Solution to each well. Cover with a film sealer and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold in universal diluent before adding it to the plate to minimize matrix effects. When calculating sample concentration, multiply the dilution factor. It is recommended to run replicates for all samples and standards.) 3. Plate Wash: Discard the remaining liquid. Add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the solution, and pat dry on absorbent paper. Repeat this process five times (a plate washer can also be used). 4. Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film sealer and incubate at 37°C for 30 minutes. 5. Washing: Discard the liquid and wash the plate five times as in step 3. 6. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with sealing film, and incubate at 37°C in the dark for 15 minutes. 7. Adding stop solution: Remove the plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot a four-parameter logistic function standard curve on double-logarithmic graph paper with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.
Sensitivity 7.2 pg/mL
Theory This kit uses a competitive enzyme-linked immunosorbent assay (ELISA). Sample, standard, and HRP-labeled antigen are sequentially added to microwells pre-coated with prostaglandin E1 (PGE1) antibodies. After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is negatively correlated with the amount of prostaglandin E1 (PGE1) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source All
Synonym General Prostaglandin E1 ELISA Kit
Detection Type Competition Law
Composition
Name 9 6 T Configuration  style="height: 10px; width: 29.98%; text-align: center;" width="29.9800%">Remarks
Pre-coated 96-well enzyme plate 8 holes×12 strips None
Standard 2 bottles
Dilution according to the instructions
Universal diluent
2×20mL
None
Concentrated Biotin-Antibody 100×
60uL
Dilute according to instructions
Concentrated enzyme conjugate 100×
120uL
Dilution according to the instructions
20×Washing solution
width="19.0000%">
2×10mL
Dilute according to instructions
Substrate (TMB)
10mL
None
Stop solution
6mL
none
Sealing film
4 sheets
None
Instructions
1 serving
None
Background Prostaglandin E1 (PGE1) is a naturally occurring prostaglandin with numerous medical uses. Aprostadil and misoprostol are synthetic forms of PGE1 and are used as medications. Lubiprostone, a derivative of PGE1, is also used as a medication. It has various effects in the body, including opening blood vessels, relaxing smooth muscle, inhibiting clotting, and inducing uterine contractions. Alprostadil is used for two primary purposes: treating newborns with congenital heart defects and treating erectile dysfunction.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 15.6-1000 pg/mL
Applications Serum, plasma, tissue homogenate, cell culture supernatant, cell lysate and other biological samples

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)