Product Details
Product Details
Product Specification
| Stability & Storage | Store away from light at 2-8℃; product shelf life is 12 months. |
Background
The Homogeneous Immuno Chemiluminescence Assay (HICA) is a homogeneous immunoassay method based on energy transfer between donor beads and acceptor beads at close proximity, resulting in luminescence.
Donor beads recognize Protein 1 (Tag1 label), while Acceptor beads recognize Protein 2 (Tag2 label). When Protein 1 binds to Protein 2, the distance between the beads becomes less than 200 nm. Upon excitation at 680 nm, the donor beads generate singlet oxygen, which diffuses to the Acceptor beads. The Acceptor beads then undergo a redox reaction, emitting light at 615 nm. The signal intensity is directly proportional to the strength of the protein interaction.
This product features a simple operation process, requires no washing, and offers high speed and sensitivity, enabling the detection of weak interactions.

Components
Name |
Main Component |
3000T |
Reagent A |
Anti-GST-tag antibody-crosslinked acceptor Beads |
10mL |
Reagent B |
Biotin-labeled anti-mouse IgG antibody |
10mL |
Reagent D |
Streptavidin Donor Beads |
10mL |
Protocol
```html
[Required Reagents]
Name |
Catalog No. |
Universal Buffer 4 |
UA086115 |
[Detection Protocol for Reference]
Detection Step |
Procedure |
Step 1: |
Add GST-tag antigen to Reagent A at 0.5μg/mL concentration |
Step 2: |
Mix Reagent A, B, and D uniformly at a 1:1:1 volume ratio, protect from light/green light |
Step 3: |
Add 10μL test sample + 10μL mixed reagent per test, protect from light/green light |
Incubation |
37°C shaking incubation for 60 minutes, protect from light/green light |
Reading |
Instrument reading |
[Sample and Reagent Preparation]
•Pre-dilute M-1b antibody to 1000ng/mL (6.67nM) with Universal Buffer 4 as C8, then perform serial dilution as follows:
ID |
Concentration (ng/mL) |
Universal Buffer 4 Volume (μL) |
High-Concentration Addition Volume (μL) |
C8 |
1000 |
/ |
/ |
C7 |
200 |
160 |
40μL C8 |
C6 |
40 |
160 |
40μL C7 |
C5 |
8 |
160 |
40μL C6 |
C4 |
1.6 |
160 |
40μL C5 |
| Name | Catalog No. | ||
|---|---|---|---|
| Universal Buffer 4 | UA086115 |
[Procedure]
| Step | Action |
|---|---|
| 1 | Add GST-tag antigen (0.5μg/mL) to Reagent A |
| 2 | Mix A:B:D (1:1:1), light-sensitive |
| 3 | Add 10μL sample + 10μL mixed reagent, light-sensitive |
| Incubation | 37°C, 60min, light-sensitive |
| Reading | Instrument measurement |
[Sample Prep]
| ID | Conc.(ng/mL) | Buffer(μL) | Add(μL) |
|---|---|---|---|
| C8 | 1000 | - | - |
| C7 | 200 | 160 | 40 C8 |
[Validation]
- Dose-response: Max=1,830,280, Min=943, EC50=126.5ng/mL (0.84nM)
- LoB: 0.099ng/mL (0.66pM)
- CV%: Low=2.2%, High=1.1%
- Specificity: Human IgG=0%, Rabbit IgG=0%