Monkey INS ELISA Kit

Monkey INS ELISA Kit

Catalog Number: abs554114 Application: ELISA Reactivity: Monkey Conjugation:
Price:
Regular price $460.32 USD
Regular price Sale price $460.32 USD
Size:
For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification

Usage I. Sample Handling and Requirements: 1. The detection range of the kit is not equivalent to the concentration range of the analyte in the sample. Before the experiment, it is recommended to estimate the analyte concentration in the sample based on relevant literature and conduct preliminary experiments to determine the actual concentration. If the analyte concentration in the sample is too high or too low, please dilute or concentrate the sample appropriately. 2. If the sample type to be tested is not listed in the instructions, it is recommended to conduct preliminary experiments to verify the validity of the assay. 3. Serum: Collect whole blood in a serum separator tube and incubate at room temperature for 2 hours or at 2-8°C overnight. Then, centrifuge at 1000×g for 20 minutes. The supernatant can be collected or stored at -20°C or -80°C. Avoid repeated freezing and thawing. 4. Plasma: Collect the sample using EDTA or heparin as an anticoagulant. Centrifuge the sample at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing. 5. Tissue Homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate may affect test results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted based on experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and thoroughly grind on ice or in a homogenizer. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes and collect the supernatant for analysis. 6. Cell Culture Supernatant: Centrifuge at 1000 × g for 20 minutes. Collect the supernatant for analysis or store at -20°C or -80°C, but avoid repeated freeze-thaw cycles. 7. Cell Lysis Buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and harvest by centrifugation at 1000 × g for 5 minutes. Suspension cells can be harvested directly by centrifugation. Wash harvested cells three times with ice-cold PBS and resuspend in 150-200 μL of PBS per 1 × 10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500 × g for 10 minutes at 2-8°C. Remove the supernatant for testing. 8. Other biological samples: Centrifuge at 1000 × g for 20 minutes. Remove the supernatant for testing. 9. Sample Appearance: The sample should be clear and transparent, and any suspended matter should be removed by centrifugation. 10. Sample Storage: If testing is to be performed within one week of collection, the sample can be stored at 4°C. If testing is not possible, aliquot the sample into a single-use amount and freeze at -20°C (for testing within one month) or -80°C (for testing within six months). Avoid repeated freeze-thaw cycles. Hemolysis of the sample can affect the final test results, so hemolyzed samples are not suitable for this test. Sample Dilution Protocol: Please estimate the sample concentration range in advance. If your test sample requires dilution, the following dilution protocol is recommended: 100-fold dilution: One-step dilution. Add 5µL of sample to 495µL of universal diluent for a 100-fold dilution. 1000-fold dilution: Two-step dilution. Add 5µL of sample to 95µL of universal diluent for a 20-fold dilution. Then, add 5µL of the 20-fold diluted sample to 245µL of universal diluent for a 50-fold dilution, for a total of 1000-fold dilution. 100,000-fold dilution: Three-step dilution. Add 5µL of sample to 195µL of universal diluent and dilute 40-fold. Then, add 5µL of the 40-fold diluted sample to 245µL of universal diluent and dilute 50-fold. Finally, add 5µL of the 2000-fold diluted sample to 245µL of universal diluent and dilute 50-fold, for a total dilution of 100,000-fold. For each dilution step, use at least 3µL of sample, and do not exceed a 100-fold dilution. Mix thoroughly at each dilution step to avoid foaming. 2. Equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision pipettes and tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C constant temperature box 4. Distilled or deionized water III. Preparation before testing: 1. Please take out the test kit from the refrigerator 10 minutes in advance and equilibrate it to room temperature. 2. Preparation of Gradient Standard Working Solution: Add 1 mL of Universal Diluent to the lyophilized standard. Let stand for 15 minutes to completely dissolve, then gently mix (concentration 100 uIU/mL). Then dilute to the following concentrations: 100 uIU/mL, 50 uIU/mL, 25 uIU/mL, 12.5 uIU/mL, 6.25 uIU/mL, 3.12 uIU/mL, 1.56 uIU/mL, and 0 uIU/mL. Serial Dilution Method: Add 500 uL of Universal Diluent to each of seven EP tubes. Pipette 500 uL of the 100 uIU/mL standard working solution into the first EP tube and mix thoroughly to make a 50 uIU/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube is directly used as a blank well, and there is no need to draw liquid from the penultimate tube, as shown in the figure below.


3. Preparation of biotinylated antibody working solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute 100×concentrated biotinylated antibody to a 1×working concentration with universal diluent (e.g., 10 μL concentrate + 990 μL 4. Preparation of enzyme conjugate working solution: 15 minutes before use, centrifuge 100 μL of concentrated enzyme conjugate at 1000 μg for 1 minute. Dilute the 100 μL concentrated HRP enzyme conjugate to a working concentration of 1 μL with universal diluent (e.g., 10 μL concentrate + 990 μL universal diluent). Prepare and use immediately. 5. Preparation of 1× Wash Buffer: Dissolve 10 mL of 20× Wash Buffer in 190 mL of distilled water. (Concentrated Wash Buffer removed from the refrigerator may crystallize, which is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing.) IV. Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return them to 4°C. 2. Sample Addition: Add 50 μL of sample or standard of varying concentrations to the corresponding wells. Add 50 μL of Universal Diluent to the blank wells, followed by 50 μL of Biotin-Antibody Working Solution to each well. Cover with sealant and incubate at 37°C for 1 hour. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate for testing to reduce the influence of matrix effects on the test results. The final calculation of sample concentration should be multiplied by the corresponding dilution factor. It is recommended to set up duplicate wells for all test samples and standards.) 3. Adding Biotinylated Antibody: Remove the ELISA plate and discard the liquid. Do not wash. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film sealer and incubate at 37°C for 60 minutes. 4. Washing: Discard the liquid. Add 300 μL of 1x Wash Solution to each well. Let it stand for 1 minute. Shake off the wash solution and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Adding Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film sealer and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times according to the washing method in step 3. 7. Add substrate: Add 90 μL of substrate (TMB) to each well, cover with sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Add stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. V. Calculation of experimental results: 1. Calculate the average OD value of the standard and sample replicate wells and subtract the OD value of the blank well as the correction value. Plot the standard curve for the four-parameter logistic function on double-logarithmic graph paper, using concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor when calculating the sample concentration.
Typical Data and Reference Curves:
The following data and curves are for reference only. Experimenters should establish a standard curve based on their own experiments.

Concentration (uIU/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD  value 2.51 1.82 1.2 0.72 0.46 0.3 0.21 0.09
Corrected OD  value 2.42 1.73 1.11 0.63 0.37 0.21 0.12 -



Sample type
Range (%) Average recovery (%)
Serum (n=8) 84-101
Dilution ratio Recovery rate (%) Serum Plasma
1:2 Range 84-95 88-96
Average recovery rate 91 93
1:4 Range 89-103 87-108
Average recycling rate 93 98


8. Problem analysis:



Problem description Possible causes Countermeasures
Poor linearity of the marking curve Incorrect dilution of standards Ensure that standards are dissolved and diluted according to the recommended method
Inaccurate pipetting Calibrate pipettes regularly and check the seal of pipette tips
Evaporation of reaction solution Seal the ELISA plate with sealing film
Incomplete plate washing Enough washing times and adding sufficient washing solution
Foreign matter on the bottom of the well Clean the bottom of the plate before reading
Weak or no color Ensure incubation time
Incorrect incubation temperature Incubate at recommended temperature
Insufficient reagent volume Check the pipette and strictly follow the operating procedures
Incorrect dilution Check reagent dilution steps
Enzyme conjugate inactivated Mix enzyme conjugate and substrate and check by colorimetric reaction
OD value is low The microplate reader is not set up correctly Check the wavelength of the instrument
No stop solution is added Add appropriate amount of stop solution
Waiting time for reading the plate is too long Read the plate in time
The sample content is too high Determine the appropriate dilution factor through preliminary experiments
The sample content is too low Determine the appropriate dilution factor through preliminary experiments
The background is high The color developing solution is contaminated Replace the color developing solution
The color developing time is too long Control the color developing time
The antibody or enzyme conjugate is diluted incorrectly Use the recommended dilution method
Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with monkey insulin (INS) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of monkey insulin (INS) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Monkey
Synonym Monkey Insulin (INS) ELISA Kit
Detection Type Double antibody sandwich method
Description Insulin (INS) is a peptide hormone produced by pancreatic beta cells that regulates the metabolism of carbohydrates, fats, and proteins by promoting the uptake of glucose from the blood into liver, adipose, and skeletal muscle cells. In these tissues, the absorbed glucose is either converted into glycogen through glycation, into fat (triglycerides) through lipogenesis, or, in the case of the liver, into both.
Composition
Name 9 6 T Configuration  style="height: 10px; width: 29.98%; text-align: center;" width="29.9800%">Storage Conditions after Opening
Pre-coated 96-well ELISA plate 8 wells ×12 strips -20℃
Pre-coated 96-well ELISA plate 8 wells ×12 strips -20℃
Standard 2 bottles
-20℃ , use on the same day after reconstitution
Universal Diluent
2×20mL
2-8℃
Concentrated biotinylated detection antibody (100×) 
120uL
-20℃
Concentrated enzyme conjugate (100×)
120uL
-20℃ (avoid light)
20×Washing liquid
2×10mL
2-8℃
Substrate (TMB)
10mL
2-8℃ (protect from light)
Stop solution
6mL
2-8℃
Sealing film
4 sheets
None
Instructions
1 portion
none
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out excessively during the entire process.
3. Clean the bottom of the plate of any residual liquid and fingerprints, as this may affect the OD value.
4. The substrate developer solution should be colorless; substrate solution that has turned blue should not be used.
5. Avoid cross-contamination of reagents and samples to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching agents or the strong fumes emitted by bleaching agents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components from different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and the samples and testing devices should be handled according to the prescribed procedures.
Storage Temp. Store at 2-8°C.
Test Range 1.56-100 uIU/mL