Product Details
Product Details
Product Specification
| Stability & Storage | Store at 2-8°C protected from light; product shelf life is 12 months. |
Background
Homogeneous Immuno Chemiluminescence Assay (HICA) is a homogeneous immunoassay method based on energy transfer between donor beads and acceptor beads at close proximity to generate luminescence.
Donor beads recognize protein 1 (Tag1 label), while acceptor beads recognize protein 2 (Tag2 label). When protein 1 binds to protein 2, the distance between the beads becomes less than 200nm. Upon excitation at 680nm, the donor beads generate singlet oxygen, which diffuses to the acceptor beads. The acceptor beads then undergo a redox reaction, emitting light at 615nm. The signal intensity is proportional to the strength of protein interaction.
This product features a simple operation process, requires no washing, and offers high speed and sensitivity. It is capable of detecting weak interactions.

Components
Name |
Main Component |
3000T |
Reagent A |
Anti-Flag-tag antibody-crosslinked acceptor Beads |
10mL |
Reagent B |
Biotin-labeled anti-human IgG antibody |
10mL |
Reagent D |
Streptavidin Donor Beads |
10mL |
Protocol
[Required Reagents]
Name |
Catalog No. |
Universal Buffer 4 |
UA086115 |
[Reference Detection Protocol]
Assay Procedure |
Assay Procedure |
Step 1: |
Add Flag-tag antigen to Reagent A at a concentration of 1.5 μg/mL |
Step 2: |
Mix Reagents A, B, and D uniformly at a volume ratio of 1:1:1,Protect from light / Green light |
Step 3: |
Add 10 μL of test sample + 10 μL of mixed reagent to each test,Protect from light / Green light |
Incubation |
Shake incubate at 37°C for 60 minutes,Protect from light / Green light |
Reading |
Instrument reading |
[Sample & Reagent Preparation]
•Pre-dilute human anti-IL1B antibody to 1000 ng/mL (6.67 nM) using DMEM + 10% FBS as C8, then perform serial dilutions according to the following scheme:
ID |
Concentration (ng/mL) |
Diluent Volume (μL) |
Antibody Volume (μL) |
C8 |
1000 |
/ |
/ |
C7 |
200 |
160 |
40μL C8 |
C6 |
40 |
160 |
40μL C7 |
C5 |
8 |
160 |
40μL C6 |
C4 |
1.6 |
160 |
40μL C5 |
C3 |
0.32 |
160 |
40μL C4 |
C2 |
0.064 |
160 |
40μL C3 |
C1 |
0 |
160 |
/ |
[Performance Validation]
•Standard Curve:

Maximum Signal: 935617
Minimum Signal: 447
EC50= 2.045 ng/mL (0.014 nM)
•Limit of Blank (LOB):
Test C1 repeatedly 20 times, calculate the mean signal and SD. Use the standard curve to calculate the concentration corresponding to mean signal + 2×SD, which is defined as the LOB.
LOB = 0.393 ng/mL (2.618 pM)
•Repeatability:
Test high and low concentration samples repeatedly 10 times each, and calculate the concentration CV%.
Repeatability |
Low Concentration |
High Concentration |
CV% |
5.0% |
3.7% |
•Specificity: Dilute the following proteins to 1 μg/mL using DMEM + 10% FBS, and test for cross-reactivity interference.
Analyte |
Cross-reactivity (%) |
Mouse anti-IL1B antibody |
0.00% |
Guidelines