Skip to product information
1 of 1

Human CEACAM1 ELISA Kit

Human CEACAM1 ELISA Kit

Catalog Number: abs5510738 Application: ELISA Reactivity: Human Conjugation:
Price:
Regular price $444 USD
Regular price Sale price $444 USD
Size:

For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification

protein CEACAM1
Usage ```html

Sample collection preparation and preservation

1. Serum: Whole blood sample placed at room temperature 2 Hour or 4°C Overnight after 1000×g Centrifugation 20 Minutes, take the supernatant to detect.
The blood collection tubes shall be disposable non-pyrogenic, non-endotoxin tubes.
deposit -20°C Or -80°C Storage, avoid repeated freezing and thawing.

2. Plasma: Sample after collection 30 Within minutes 2-8°C 、 1000×g Centrifugation 15 Minutes, take the supernatant to detect.
Anticoagulants recommended EDTA-Na2 , avoid using hemolytic, hyperlipidemic samples.
deposit -20°C Or -80°C Storage, avoid repeated freezing and thawing.

3. Tissue homogenate: Take an appropriate amount of tissue block and add it to the pre-cooled PBS ( 0.01M , pH7.0-7.2 ) to remove blood (lysed red blood cells in the homogenate will affect the measurement result), cut the tissue into pieces after weighing, and then mix it with the corresponding volume of PBS (generally according to 1:9 The mass-to-volume ratio, the specific volume can be appropriately adjusted according to the needs of the experiment, and recorded.
It is recommended to PBS Adding a protease inhibitor) into a glass homogenizer and fully grinding on ice;
In order to further lyse tissue cells, the homogenate can be subjected to ultrasonic disruption or repeated freeze-thaw treatment (pay attention to ice bath cooling during ultrasonic disruption, and the repeated freeze-thaw method can be repeated 2 Times).
Finally, the prepared homogenate is mixed in 5000×g Centrifugation 5-10 Minutes, take the supernatant to detect.
(Tissue homogenates require simultaneous detection of protein concentrations to obtain a more accurate test substance concentration per milligram of protein.)

4. Cell culture supernatant: Take the cell supernatant from 1000×g Centrifugation 20 Minutes, impurities and cell debris were removed.
Take the supernatant to detect and place it in -20°C Or -80°C Store, but repeated freezing and thawing should be avoided.

5. Urine: Please collect the first urine in the morning (mid-section urine), or 24 Hourly urine, 2000×g Centrifugation 15 The supernatant was collected after minutes and the sample was saved At -20°C And repeated freezing and thawing should be avoided.

6. Saliva: A sample is collected with a saliva sample collection tube, and then 2-8°C, 1000×g Centrifugation 15 Minutes, take the supernatant to detect, or sub-package -20°C Save.
Avoid repeated freezing and thawing.

7. Other biological samples: Please 1000×g Centrifugation 20 Minutes, take the supernatant to detect.

Notes

1. The sample should be clear and transparent, and the suspended solids should be removed by centrifugation.
Hemolysis of the sample will affect the results, so hemolyzed samples should not be used.

2. After sample collection, if 1 Testing within weeks can be stored at 4°C , if it cannot be detected in time, please pack it according to the one-time usage amount and freeze it in -20°C ( 1 Within months), or -80°C ( 3-6 Test within a month) to avoid repeated freezing and thawing.
Keep the sample at room temperature prior to the experiment.

Principles of sample dilution

If your test sample needs to be diluted, refer to the general dilution principles below:

1. Dilution 50 Times: One-step dilution.
Take 5 μL Sample to 245 μL Standard & In the sample dilution, is 50 Double dilution;

2. Dilution 100 Times: One-step dilution.
Take 5 μL Sample to 495 μL Standard & In the sample dilution, is 100 Double dilution;

3. Dilution 1000 Times: Two-step dilution.
Take 5 μL Sample to 95 μL Standard & In the sample dilution, is 20 Dilute, and then take 5 μL 20 Double dilute sample to 245 μL Standard & In the sample dilution, is 50 Double dilution, co-dilution 1000 Times;

4. Dilution 100000 Times: Three-step dilution.
Take 5 μL Sample to 195 μL Standard & In the sample dilution, is 40 Dilute, and then take 5 μL 40 Double dilute sample to 245 μL Standard & In the sample diluent, do 50 Time dilution, and finally take 5 μL 2000 Double dilute sample to 245 μL Standard & In the sample diluent, do 50 Double dilution, total dilution 100000 Times;

5. The amount of liquid taken during each dilution step is not less than 3 μL , the dilution factor is not more than 100 Times.
Too small sampling volume can easily cause greater errors in the mixing process, and each dilution step needs to be mixed evenly to avoid foaming.

6. When the dilution factor is very high, you can use it first PBS Dilution, last step using standard in kit & Sample dilution.

Sample dilution recommendations

1. Normal fresh serum / Plasma Sample Recommendation (Original solution) Testing.

2. Due to individual variations, the recommended dilution factor is for informational purposes only.
For actual testing, please estimate the concentration range of the sample in advance, and determine the dilution factor of the sample to be tested through pre-experiments.

Preparation for testing

1. Please advance 30 Minutes remove the kit from the refrigerator and equilibrate to room temperature.

2. Use double distilled water 25× The concentrated wash liquid is diluted to 1× Working fluid, put back unused 4°C 。

3. Standard: Add standard & Sample Universal Diluent 1.0 mL Into the lyophilized standard, screw the tube cap tightly and let stand 10 Minutes, and after it is fully dissolved, gently mix (concentration of 100 ng/mL )。
Thereafter, double dilution is carried out to 100 ng/mL , 50 ng/mL , 25 ng/mL , 12.5 ng/mL , 6.25 ng/mL , 3.13 ng/mL , 1.57 ng/mL Standard dilution ( 0 ng/mL ) is a blank hole.
Configure the standard according to the amount you need for later use.
The configured standards are recommended in 15 Add the sample within minutes, and it is not recommended to leave it for too long.

4. Biotinylated antibody working solution: calculate the dosage required for the current experiment before the experiment (according to 100 μL/ Hole meter, should be configured more in actual configuration 100-200 μL ), before use 15 Min, concentrated biotinylated antibody was diluted with biotinylated antibody diluent ( 1:100 ) into working concentration, use on the same day.
Dilution principle 1 μL Concentrated biotinylated antibody is added to 99 μL In the biotinylated antibody dilution, mix well with a pipette.

5. Enzyme conjugate working solution: calculate the dosage required for the current experiment before the experiment (according to 100 μL/ Hole meter, should be configured more in actual configuration 100-200 μL )。
Before use 15 Minutes, dilute and concentrate with enzyme conjugate diluent HRP Enzyme conjugate ( 1:100 ) into working concentration, use on the same day.
Dilution principle 1 μL The concentrated enzyme conjugate is added to 99 μL The enzyme conjugate dilution was mixed with a pipette.

6.TMB Substrate —— Pipette the desired dose of solution and do not pour the residual solution back into the reagent vial again.

Notes

1. Please make sure that all components are dissolved and mixed before use of the kit.
If the reconstituted standard is not used, please discard it.

2. Concentrated biotinylated antibody, the volume of concentrated enzyme conjugate is small, may be dispersed in various parts of the tube during transportation, please 1000×g Centrifugation 1 Minutes to allow the liquid of the tube wall or cap to deposit to the bottom of the tube.
Pipette carefully before use 4-5 The solution was mixed once.
Standard, biotinylated antibody working solution and enzyme conjugate working solution should be prepared according to the required dosage, and the corresponding diluent should be use

Species Reactivity Human
Theory This kit adopts the principle of sandwich method. The specific anti-human CEACAM1 antibody was coated in a 96-well microplate, and the human CEACAM1 standard or sample was added to the microwells, so that the human CEACAM1 protein in the standard or the human CEACAM1 protein in the sample was bound to the anti-human CEACAM1 antibody solid on the microplate, then biotinylated anti-human CEACAM1 antibody was added, the unbound biotinylated antibody was washed, HRP-labeled streptavidin was added, and then TMB substrate was added to develop color. TMB is converted to blue under peroxidase catalysis and to final yellow under the action of acid. There was a positive correlation between the depth of color and the human CEACAM1 protein in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the sample concentration was calculated by drawing a standard curve.
Source Human
Synonym Human CEACAM1(Carcinoembryonic Antigen Related Cell Adhesion Molecule 1) ELISA Kit
Detection Type Human CEACAM1 can be detected in a sample without cross-reaction with other related proteins
Composition

Chinese Name

96T

Preservation conditions

Enzyme labeled plate (detachable)

12 Strip x 8 Hole

4°C/-20°C

Lyophilized Standard

2

4°C/-20°C

Standard & Sample dilution

20 mL

4°C/-20°C

Concentrated biotinylated antibodies ( 100× )

120 μL

4°C/-20°C

Biotinylated antibody dilution

12 mL

4°C/-20°C

concentrate HRP Enzyme conjugate ( 100× )

120 μL

4°C/-20°C

Enzyme conjugate dilution

12 mL

4°C/-20°C

Concentrated wash ( 25× )

20 mL

4°C/-20°C

Chromogenic substrate solution ( TMB )

10 mL

4°C/-20°C( Protected from light)

Reaction stop solution

6 mL

4°C/-20°C

Sealing film

2

normal temperature

General Notes

1. If the entire kit is stored at-20 °C, please place the kit at 4 °C the night before the experiment.

2. Salt precipitation will occur when the concentrated washing liquid is stored at low temperature. When diluted, it can be heated in a water bath to help dissolve.

3. The newly opened wells of the enzyme labeled plate may contain a little water-like substance, which is a normal phenomenon and will not have any impact on the experimental results.

4. This kit is intended for laboratory research and development use only, not for human or animal use.

5. Reagents should be treated as hazardous substances and should be handled carefully and properly disposed of.

6. Gloves, lab coats and protective glasses should always be worn to avoid skin and eye contact with terminating solution and TMB. In case of accidental contact, please wash thoroughly with water.

Storage Temp. Kit unopened, stored at 4 °C, shelf life 6 months.
Test Range Detection range: 1.57-100 ng/mL; Sensitivity: 0.59 ng/mL