Product Details
Product Details
Product Specification
| protein | CEACAM1 | ||||||||||||||||||||||||||||||||||||
| Usage | ```html
Sample collection preparation and preservation 1. Serum: Whole blood sample placed at room temperature 2 Hour or 4°C Overnight after 1000×g Centrifugation 20 Minutes, take the supernatant to detect. 2. Plasma: Sample after collection 30 Within minutes 2-8°C 、 1000×g Centrifugation 15 Minutes, take the supernatant to detect. 3. Tissue homogenate: Take an appropriate amount of tissue block and add it to the pre-cooled PBS ( 0.01M , pH7.0-7.2 ) to remove blood (lysed red blood cells in the homogenate will affect the measurement result), cut the tissue into pieces after weighing, and then mix it with the corresponding volume of PBS (generally according to 1:9 The mass-to-volume ratio, the specific volume can be appropriately adjusted according to the needs of the experiment, and recorded. 4. Cell culture supernatant: Take the cell supernatant from 1000×g Centrifugation 20 Minutes, impurities and cell debris were removed. 5. Urine: Please collect the first urine in the morning (mid-section urine), or 24 Hourly urine, 2000×g Centrifugation 15 The supernatant was collected after minutes and the sample was saved At -20°C And repeated freezing and thawing should be avoided. 6. Saliva: A sample is collected with a saliva sample collection tube, and then 2-8°C, 1000×g Centrifugation 15 Minutes, take the supernatant to detect, or sub-package -20°C Save. 7. Other biological samples: Please 1000×g Centrifugation 20 Minutes, take the supernatant to detect. Notes 1. The sample should be clear and transparent, and the suspended solids should be removed by centrifugation. 2. After sample collection, if 1 Testing within weeks can be stored at 4°C , if it cannot be detected in time, please pack it according to the one-time usage amount and freeze it in -20°C ( 1 Within months), or -80°C ( 3-6 Test within a month) to avoid repeated freezing and thawing. Principles of sample dilution If your test sample needs to be diluted, refer to the general dilution principles below: 1. Dilution 50 Times: One-step dilution. 2. Dilution 100 Times: One-step dilution. 3. Dilution 1000 Times: Two-step dilution. 4. Dilution 100000 Times: Three-step dilution. 5. The amount of liquid taken during each dilution step is not less than 3 μL , the dilution factor is not more than 100 Times. 6. When the dilution factor is very high, you can use it first PBS Dilution, last step using standard in kit & Sample dilution. Sample dilution recommendations1. Normal fresh serum / Plasma Sample Recommendation (Original solution) Testing. 2. Due to individual variations, the recommended dilution factor is for informational purposes only. Preparation for testing 1. Please advance 30 Minutes remove the kit from the refrigerator and equilibrate to room temperature. 2. Use double distilled water 25× The concentrated wash liquid is diluted to 1× Working fluid, put back unused 4°C 。 3. Standard: Add standard & Sample Universal Diluent 1.0 mL Into the lyophilized standard, screw the tube cap tightly and let stand 10 Minutes, and after it is fully dissolved, gently mix (concentration of 100 ng/mL )。 4. Biotinylated antibody working solution: calculate the dosage required for the current experiment before the experiment (according to 100 μL/ Hole meter, should be configured more in actual configuration 100-200 μL ), before use 15 Min, concentrated biotinylated antibody was diluted with biotinylated antibody diluent ( 1:100 ) into working concentration, use on the same day. 5. Enzyme conjugate working solution: calculate the dosage required for the current experiment before the experiment (according to 100 μL/ Hole meter, should be configured more in actual configuration 100-200 μL )。 6.TMB Substrate —— Pipette the desired dose of solution and do not pour the residual solution back into the reagent vial again. Notes 1. Please make sure that all components are dissolved and mixed before use of the kit. 2. Concentrated biotinylated antibody, the volume of concentrated enzyme conjugate is small, may be dispersed in various parts of the tube during transportation, please 1000×g Centrifugation 1 Minutes to allow the liquid of the tube wall or cap to deposit to the bottom of the tube. |
||||||||||||||||||||||||||||||||||||
| Species Reactivity | Human | ||||||||||||||||||||||||||||||||||||
| Theory | This kit adopts the principle of sandwich method. The specific anti-human CEACAM1 antibody was coated in a 96-well microplate, and the human CEACAM1 standard or sample was added to the microwells, so that the human CEACAM1 protein in the standard or the human CEACAM1 protein in the sample was bound to the anti-human CEACAM1 antibody solid on the microplate, then biotinylated anti-human CEACAM1 antibody was added, the unbound biotinylated antibody was washed, HRP-labeled streptavidin was added, and then TMB substrate was added to develop color. TMB is converted to blue under peroxidase catalysis and to final yellow under the action of acid. There was a positive correlation between the depth of color and the human CEACAM1 protein in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the sample concentration was calculated by drawing a standard curve. | ||||||||||||||||||||||||||||||||||||
| Source | Human | ||||||||||||||||||||||||||||||||||||
| Synonym | Human CEACAM1(Carcinoembryonic Antigen Related Cell Adhesion Molecule 1) ELISA Kit | ||||||||||||||||||||||||||||||||||||
| Detection Type | Human CEACAM1 can be detected in a sample without cross-reaction with other related proteins | ||||||||||||||||||||||||||||||||||||
| Composition |
|
||||||||||||||||||||||||||||||||||||
| General Notes |
1. If the entire kit is stored at-20 °C, please place the kit at 4 °C the night before the experiment. 2. Salt precipitation will occur when the concentrated washing liquid is stored at low temperature. When diluted, it can be heated in a water bath to help dissolve. 3. The newly opened wells of the enzyme labeled plate may contain a little water-like substance, which is a normal phenomenon and will not have any impact on the experimental results. 4. This kit is intended for laboratory research and development use only, not for human or animal use. 5. Reagents should be treated as hazardous substances and should be handled carefully and properly disposed of. 6. Gloves, lab coats and protective glasses should always be worn to avoid skin and eye contact with terminating solution and TMB. In case of accidental contact, please wash thoroughly with water. |
||||||||||||||||||||||||||||||||||||
| Storage Temp. | Kit unopened, stored at 4 °C, shelf life 6 months. | ||||||||||||||||||||||||||||||||||||
| Test Range | Detection range: 1.57-100 ng/mL; Sensitivity: 0.59 ng/mL |