Product Details
Product Details
Product Specification
| Usage |
Sample Processing and Requirements 1. 2. 3. 4. Reagent Preparation Procedure 2. 3. 4. 5. 6. 7. Calculation of Experimental Results: |
||||||||||||||||||||||||||||||
| Sensitivity | The minimum detectable concentration was less than 10 pg/mL. | ||||||||||||||||||||||||||||||
| Species Reactivity | Human | ||||||||||||||||||||||||||||||
| Theory | The kit utilizes a double-antibody, one-step sandwich enzyme-linked immunosorbent assay (ELISA). Samples, standards, and HRP-labeled detection antibodies are sequentially added to microwells pre-coated with a capture antibody against human hepatocyte nuclear factor 4α (HNF4α). The sample is incubated and washed thoroughly. The color is developed using the substrate TMB, which converts to blue under the catalysis of peroxidase and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of human hepatocyte nuclear factor 4α (HNF4α) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | ||||||||||||||||||||||||||||||
| Detection Type | Used for in vitro quantitative detection of the content of human hepatocyte nuclear factor 4α (HNF4α) in serum, plasma, tissue homogenate and related liquid samples. | ||||||||||||||||||||||||||||||
| Composition |
Remarks: 1. The concentrations of the standard solutions are: 1600, 800, 400, 200, 100, and 50 pg/mL. 2. After testing a large number of normal specimens, the normal concentration values of the specimens are all within the detection range provided by the kit. During the experiment, 50 μL of sample can be directly sampled. If some sample values exceed the maximum standard concentration, the sample can be appropriately diluted with sample diluent before the experiment. |
||||||||||||||||||||||||||||||
| General Notes |
1. Strictly follow the specified incubation time and temperature to ensure accurate results. All reagents must reach room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing can lead to inaccurate results. Ensure that the liquid in the wells is as dry as possible before adding substrate. Do not allow the microwells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, otherwise it will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Substrate solution that has turned blue should not be used. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Allow the sealed bag to equilibrate to room temperature before opening to prevent water droplets from condensing on the cold plate strips. 8. No reaction reagents should come into contact with bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching component will destroy the biological activity of the reagents in the kit. 9. Do not use expired products. 10. If there is a possibility of disease transmission, all samples should be managed properly and the samples and detection devices should be handled according to the prescribed procedures. |
||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened test kit is sealed and stored at 2-8°C, it is valid for 6 months. | ||||||||||||||||||||||||||||||
| Test Range | 50 pg/mL – 1600 pg/mL. |