Product Details
Product Details
Product Specification
| Host | Human |
| Stability & Storage | -80℃ |
Background
【ASSAY PRINCIPLE】
The kit is based on homogeneous time-resolved fluorescence technology (TR-FRET) technology,which is used to assess the interaction of RIPTAC and BRD4.
As shown in the figure below, the interaction between BRD4 and JQ-1 was detected by an Eu-labeled anti-Tag1 antibody (TR-FRET donor) and an Ac-labeled SA (TR-FRET receptor). Since the molecular JQ-1 binding to BRD4, the donor antibody is in close proximity to the receptor antibody. Excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the receptor, resulting in specific emission of a signal at a wavelength of 665 nm from the receptor. This specific signal is proportional to the degree of interaction between BRD4 and JQ-1. While the RIPTAC molecular bind to BRD4 competing with JQ-1, resulting the specific emission of a signal at a wavelength of 665 nm from the receptor decreased. This decrease of specific signal is proportional to the degree of interaction between BRD4 and RAPTIC. This homogeneous assay is simple to perform and requires no washing steps.

Components
【Composition and Storage Conditions】
Composition |
concentration |
100T |
500T |
2500T |
10000T |
Storage |
Tag1-BRD4 protein |
100× |
5μL |
20μL |
100μL |
400μL |
-80℃ |
Tag2-JQ-1 |
100× |
5μL |
20μL |
100μL |
400μL |
-80℃ |
Anti-Tag1 Eu antibody |
200× |
3μL |
13μL |
63μL |
250μL |
-80℃ |
SA Ac |
12.5× |
40μL |
200μL |
1000μL |
4mL |
-80℃ |
Detection buffer |
1× |
4mL |
20mL |
100mL |
400mL |
-80℃ |
Note: Aliquot into appropriate volumes, store at the recommended temperature and avoid repeated freeze-thaw cycle.
Protocol
【Process and Operations】
1、Reagent Preparation
1.1 Compositions equilibration
Before use, dissolve all reagents at room temperature (allow at least 30 minutes for temperature equilibration). For the 384-well plate assay, use 20 μL of reaction mixture (the reagent quantities are listed in the table below). Calculate the required volume prior to preparation accordingly. The following preparation steps are provided for reference only, using a 500-well plate as an example.
Table 1. Reagent Preparation
Composition |
Configuration |
μL/well |
Tag1-BRD4 protein |
Take 20 μL of the 100× Tag1-BRD4 protein stock solution, add 1.98 mL of 1× Detection buffer to dilute it to 1× concentration, and mix thoroughly for later use. |
4 |
Tag2-JQ-1 |
Take 20 μL of 100× Tag2-JQ1, add it to 1.98 mL of 1× Detection buffer to dilute to 1× concentration, and mix thoroughly for later use. |
4 |
Antibody Mix |
Take 12.5 μL of the 200× Anti-Tag1 Tb antibody , add 2487.5 μL of 1× Detection buffer to dilute to 2.5 mL, and mix thoroughly; take 200 μL of the 12.5× SA Ac, add 2300 μL of 1× Detection buffer to dilute to 2.5 mL, and mix thoroughly; combine the two solutions in a 1:1 ratio to obtain the Antibody Mix. |
10 |
1.2 Gradient dilution of the sample
HLD0915 as an example, the dilution solution is 1× Detection buffer. To minimize interference from matrix effects, it is recommended to use a solution with the same matrix composition as the sample being tested; additionally, the sample concentration should be adjusted according to its actual situation.
Table 2. HLD0915 gradient dilution(Adjust according to the actual situation)
HLD0915 final concentration(nM) |
HLD0915 preparation concentration(nM) |
Dilution |
|
① |
1000.00 |
10000.00 |
1μL 1000 μM HLD0915+99μL 1× Detection buffer |
② |
333.33 |
3333.33 |
20μL ① +40μL 1× Detection buffer |
③ |
111.11 |
1111.11 |
20μL ② +40μL 1× Detection buffer |
④ |
37.04 |
370.37 |
20μL ③ +40μL 1× Detection buffer |
⑤ |
12.35 |
123.46 |
20μL ④ +40μL 1× Detection buffer |
⑥ |
4.12 |
41.15 |
20μL ⑤ +40μL 1× Detection buffer |
⑦ |
1.37 |
13.72 |
20μL ⑥ +40μL 1× Detection buffer |
⑧ |
0.46 |
4.57 |
20μL ⑦+40μL 1× Detection buffer |
⑨ |
0.15 |
1.52 |
20μL ⑧+40μL 1× Detection buffer |
⑩ |
0.05 |
0.51 |
20μL ⑨+40μL 1× Detection buffer |
Blank |
0.00 |
0.00 |
40μL 1× Detection buffer |
2、Sample and control
2.1 Sample:Add 4 μL of Tag1-BRD4 protein working solution, 4 μL of Tag2-JQ-1 working solution, 2 μL of the gradient-diluted sample , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
2.2 HLD0915: 4 μL of Tag1-BRD4 protein working solution, 4 μL of Tag2-JQ-1 working solution, 2 μL of gradient-diluted HLD0915, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
2.3 Blank:4 μL of Tag1-BRD4 protein working solution, 4 μL of Tag2-JQ-1 working solution, 2 μL of Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
2.4 Negative control: 10μL Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
After adding all samples, centrifuge, seal with a cover membrane, and incubate at room temperature for 2 hours.
Table 3. Sample and control spotting process
HLD0915 |
Sample |
Blank |
Negative control (NC) |
|
2μL gradient-diluted HLD0915 |
2μL gradient-diluted sample |
2μL 1× Detection buffer |
10μL 1× Detection buffer and 10μL Antibody Mix |
4μL Tag1-BRD4 protein | |||
Incubate at room temperature for 10 mins | |||
4μL Tag2-JQ-1 | |||
10μL Antibody Mix | |||
Seal the plate wells with a sealing film and incubate at room temperature for 2 hours. | |||
3、Read Data
The detection was performed on a TR-FRET microplate reader. The excitation wavelength was 320/340 nm, and the emission wavelengths at 620 nm and 665 nm were detected.
【DATA REDUCTION 】
1) Ratio:
Ratio = (665/620) ×10000
2) Net signal:
Net signal = (Std-NC)/NC×100
Std:the ratio of sample and control
NC: the ratio of negative control
3) CV(%):
CV(%)= Standard Deviation/Mean Ratio × 100%
【Data Example】
The following data cannot replace experimental results obtained in experiments; they are provided solely for illustrative purposes, and outcomes may vary depending on the plate reader used.


Note: Recommended microplate (384-well plate, white, shallow wells).