Skip to product information
1 of 1

UniOne® TR-FRET Human BRD4/AR RIPTAC Binding Kit

UniOne® TR-FRET Human BRD4/AR RIPTAC Binding Kit

Catalog Number: UA086148 Brand: UA BIOSCIENCE
Price:
Regular price $730 USD
Regular price Sale price $730 USD
Size:

For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification


Host Human
Stability & Storage

-80℃

Background

ASSAY PRINCIPLE

The kit is based on homogeneous time-resolved fluorescence technology (TR-FRET) technology,which is used to assess the molecular-mediated interaction between the BRD4 (BD1/BD2) and the LBD of human androgen receptor (AR LBD). This method provides a high-throughput approach to detect the small molecules capable of mediating the interaction between BRD4 and AR LBD simply and rapidly .

As shown in the figure below, the interaction between BRD4 and AR LBD was detected by an Eu-labeled anti-Tag1 antibody (TR-FRET donor) and an Ac-labeled anti-Tag2 antibody (TR-FRET receptor). Since the molecular adhesive HLD0915 mediates the interaction between BRD4 and AR LBD, the donor is in close proximity to the receptor antibody. Excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the receptor antibody, resulting in specific emission of a signal at a wavelength of 665 nm from the receptor antibody. This specific signal is proportional to the degree of interaction between molecular adhesive, BRD4 and AR LBD. This homogeneous assay is simple to perform and requires no washing steps.

Components

【Composition and Storage Conditions】

Composition

concentration

100T

500T

2500T

10000T

Storage

Tag1-AR LBD

5

8μL

40μL

200μL

800μL

-80℃

Tag2-BRD4 protein

100×

5μL

20μL

100μL

400μL

-80℃

HLD0915

1 mM

5μL

10μL

50μL

200μL

-80℃

Anti-Tag1 Eu antibody

10

5μL

25μL

125μL

500μL

-80℃

Anti-Tag2 Ac antibody

100×

5μL

25μL

125μL

500μL

-80℃

Detection buffer

4mL

20mL

100mL

400mL

-80℃


Note: Aliquot into appropriate volumes, store at the recommended temperature and avoid repeated freeze-thaw cycle.

Protocol

【Process and Operations】

1、Reagent Preparation

1.1 Compositions equilibration

Before use, dissolve all reagents at room temperature (allow at least 30 minutes for temperature equilibration). For the 384-well plate assay, use 20 μL of reaction mixture (the reagent quantities are listed in the table below). Calculate the required volume prior to preparation accordingly. The following preparation steps are provided for reference only, using a 500-well plate as an example.

Table 1. Reagent Preparation

Composition

Configuration

μL/well

Tag1-AR LBD

Take 40 μL of the 5Tag1-AR LBD stock solution, add 1.96 mL of Detection buffer to dilute it to 1× concentration, and mix thoroughly for later use.

4

Tag2-BRD4 protein

Take 20 μL of 100× Tag2-BRD4 protein protein, add it to 1.98 mL of Detection buffer to dilute to 1× concentration, and mix thoroughly for later use.

4

Antibody Mix

Take 25 μL of the 10Anti-Tag1 Eu antibody stock solution, add 2475 μL of Detection buffer to dilute to 2.5 mL, and mix thoroughly; take 25 μL of the 100× Anti-Tag2 Ac antibody stock solution, add 2475 μL of Detection buffer to dilute to 2.5 mL, and mix thoroughly; combine the two solutions in a 1:1 ratio to obtain the Antibody Mix.

10


1.2 Gradient dilution of the sample

HLD0915 as an example, the dilution solution is Detection buffer. To minimize interference from matrix effects, it is recommended to use a solution with the same matrix composition as the sample being tested; additionally, the sample concentration should be adjusted according to its actual situation.

Table 2. HLD0915 gradient dilution(Adjust according to the actual situation)

HLD0915 final concentration(nM)

HLD0915 preparation concentration(nM)

Dilution

8000.00

80000.00

2.5μL 1 mM HLD0915 +28.75μL Detection buffer

2666.67

26666.67

10μL +20μL Detection buffer

888.89

8888.89

10μL +20μL Detection buffer

296.30

2962.96

10μL +20μL Detection buffer

98.77

987.65

10μL +20μL Detection buffer

32.92

329.22

10μL +20μL Detection buffer

10.97

109.74

10μL +20μL Detection buffer

3.66

36.58

10μL +20μL Detection buffer

1.22

12.19

10μL +20μL Detection buffer

0.41

4.06

10μL +20μL Detection buffer

Blank

0

0

20μL Detection buffer


2、Sample and control

2.1 Sample:Add 4 μL of Tag1-AR LBD working solution, 4 μL of Tag2-BRD4 protein working solution, 2 μL of the gradient-diluted sample , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

2.2 HLD0915: 4 μL of Tag1-AR LBD working solution, 4 μL of Tag2-BRD4 protein working solution, 2 μL of gradient-diluted HLD0915, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

2.3 Blank:4 μL of Tag1-AR LBD working solution, 4 μL of Tag2-BRD4 protein working solution,, 2 μL of Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

2.3 Negative control10μL Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

After adding all samples, centrifuge, seal with a cover membrane, and incubate at room temperature more than 6hours.

Table 3. Sample and control spotting process

HLD0915

Sample

Blank

Negative control(NC)

2μL

gradient-diluted HLD0915

2μL

gradient-diluted sample

2μL

Detection buffer

10μL Detection buffer

and 10μL Antibody Mix

4μL Tag1-AR LBD

4μL Tag2-BRD4 protein

10μL Antibody Mix

Seal the plate wells with a sealing film and incubate at room temperature more than 6 hours.


3、Read Data

The detection was performed on a TR-FRET microplate reader. The excitation wavelength was 320/340 nm, and the emission wavelengths at 620 nm and 665 nm were detected.

【DATA REDUCTION 】

1) Ratio

Ratio = (665/620) ×10000

2) Net signal

Net signal = (Std-NC)/NC×100

Std:the ratio of sample and control

NC: the ratio of negative control

3) CV(%)

CV(%)= Standard Deviation/Mean Ratio × 100%

Data Example

The following data cannot replace experimental results obtained in experiments; they are provided solely for illustrative purposes, and outcomes may vary depending on the plate reader used.

Note: Recommended microplate (384-well plate, white, shallow wells).