Skip to product information
1 of 1

Mouse GHbA1c ELISA Kit

Mouse GHbA1c ELISA Kit

Catalog Number: abs552577 Application: ELISA Reactivity: Mouse Conjugation:
Price:
Regular price $368 USD
Regular price Sale price $368 USD
Size:

For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification

Usage Self-prepared test equipment required for the experiment:
1 , plate reader ( 450nm )
2 , high-precision sampler and gun head: 0.5-10uL 、 5-50uL 、 20-200uL 、 200-1000uL
3 、 37℃℃ Incubator
4 Distilled water or deionized water,

Sample handling and requirements:
Whole blood

Preparations before testing:
1 , please advance 10 Minutes remove the kit from the refrigerator and equilibrate to room temperature.
2 , Standard gradient working solution preparation: add 1mL Universal diluent into lyophilized standard and let stand 15 Minutes until it is completely dissolved and then gently mix (the concentration is 50ug/mL )
And then according to the following concentrations: 50ug/mL 、 25ug/mL 、 12.5ug/mL 、 6.25ug/mL 、 3.125ug/mL 、 1.5625ug/mL 、 0.78125ug/mL0ug/mL The dilution was performed.
Double dilution method
: Take 7 branch EP Tube
, added to each tube 500uL Universal diluent ,50ug/mL Pipette from the standard working solution 500uL To the first EP Mix evenly in a tube 25ug/mL Standard Working Solution
, according to this step, absorb and mix evenly in turn. The last tube is directly used as a blank hole
, there is no need to suck liquid from the penultimate tube, as shown in the figure below.

3 Preparation of biotinylated antibody detection working solution: before use 15 Min. The concentrated biotinylated antibody was concentrated in 1000×g
Centrifugation
1 Minutes, with a universal diluent
100× The concentrated biotinylated antibody was diluted into
1× Working concentration (ex:
10uL
Concentrate +990uL
Universal Diluent)
, now available for use.
4 Preparation of enzyme conjugate working solution: before use
15 Minutes will 100× Concentrated enzyme conjugate in
1000×g
Centrifugation
1 Minutes, with a universal diluent
100× concentrate HRP
The enzyme conjugate is diluted into
1× Working concentration (ex: 10uL
Concentrate +990uL
Universal Diluent)
, now available for use.
5 、 1× Wash liquid preparation: Take 10mL 20× Wash liquid to
190mL
In distilled water (the concentrated washing liquid taken out of the refrigerator may have crystals, which is a normal phenomenon. It can be left at room temperature and prepared after the crystals are completely dissolved).

Operation steps:
1 Equilibration from room temperature
10 After minutes, remove the required slats from the aluminum foil bag, and seal the remaining slats with ziplock bag and put them back
4℃ 。
2 , Adding samples: respectively add samples or different concentration standards according to
100ul Each well is added to the corresponding well, and the blank well is added
100uL Universal diluent. After covering the sealing film
37℃ Incubation
60 Minutes. (Recommendation
: Minimum dilution of sample to be tested with universal diluent
1 Times later, add the enzyme labeled plate for testing. So as to reduce the influence of matrix effect on the test results, and finally, the sample concentration needs to be multiplied by the corresponding dilution factor when calculating. It is recommended to set up double wells for all samples and standards to be tested during testing).
3 Add biotinylated antibody: take out the enzyme plate, discard the liquid without washing. Directly add biotinylated antibody working solution to each well
100uL
, after covering the sealing film
37℃ Incubation
60 Minutes.
4 Plate washing: discard the liquid and add to each well
300uL 1x Wash liquid, stand
1 Minutes, throw off the washing liquid, pat dry on absorbent paper, and repeat washing the plate
3 Times (the plate can also be washed with a plate washing machine).
5 Adding enzyme conjugate working solution: adding enzyme conjugate working solution to each well
100uL
, after covering the sealing film
37℃ Incubation
30 Minutes.
6 Plate washing: discard the liquid according to the steps
4 Washing method, wash plate
5 Times.
7 Substrate addition: substrate is added per well ( TMB ) 90uL Covered with a sealing film, 37℃ Incubation protected from light
15 Minutes.
8 Add stop solution: take out the enzyme label plate and directly add stop solution to each well 50uL
, immediately in 450nm Wavelength measurement of each well OD Value.

Calculation of experimental results:
Result judgment:
1 , calculate the average of the standard and sample replica well OD Value and subtract the blank hole's OD Values as correction values. Taking concentration as the abscissa, OD Value is ordinate
, draw the standard curve of the four-parameter logic function on the double logarithmic coordinate paper.
2 If the sample OD If the value is higher than the upper limit of the standard curve, the test should be retested after appropriate dilution and multiplied by the corresponding dilution factor when calculating the sample concentration.
Theory This kit uses double antibody sandwich enzyme-linked immunosorbent assay (ELISA). To the microwells pre-coated with Glycated hemoglobin A1c (GHbA1c) capture antibody, sample, standard product, biotin-labeled detection antibody, and HRP enzyme conjugate were added sequentially, incubated and washed in the middle, and colored with substrate TMB. TMB is converted to blue under the catalysis of peroxidase (HRP) and to the final yellow under the action of acid. There was a positive correlation between the depth of color and the Glycated hemoglobin A1c (GHbA1c) in the samples. The absorbance (0D value) was measured with a microplate reader at a wavelength of 450nm, and the sample concentration was calculated.
Source Mouse
Synonym Mouse Glycated hemoglobin A1c ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 ×12 without
Standard 2
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4
without
Instructions
1
without
Background Glycosylated hemoglobin A1c (GHbA1c) is a form of hemoglobin (Hb) that is chemically linked to sugar. Most monosaccharides, including glucose, galactose, and fructose, when present in the blood, spontaneously (i.e., non-enzymatically) bind to hemoglobin. The formation of a sugar-hemoglobin junction indicates the presence of an excess of sugar in the blood, usually indicating diabetes. It is a measure of the beta-N-1-deoxyfructosyl component of hemoglobin.
General Notes 1. Carry out incubation in strict accordance with the specified time and temperature to ensure accurate results. All reagents must reach room temperature 20-25 °C prior to use. Store reagents in refrigeration immediately after use.
2. Incorrect plate washing may lead to inaccurate results. Make sure to drain the liquid from the wells as much as possible before adding the substrate. Do not allow the wells to dry out during incubation.
3. Eliminate the residual liquid and fingerprints at the bottom of the plate, otherwise it will affect the OD value.
4. The substrate color development solution should be colorless or very light in color, and the substrate solution that has turned blue cannot be used.
5. Avoid cross-contamination of reagents and specimens to avoid wrong results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Any reaction reagent cannot come into contact with the bleaching solvent or the strong gas emitted by the bleaching solvent. Any bleaching component will destroy the biological activity of the reaction reagents in the kit.
8. Expired products cannot be used, and components with different item numbers and batch numbers cannot be mixed.
9. Recombinant proteins from sources other than the kit may not match the antibodies in this kit and are not recognized.
10. If the disease may be spread, all samples should be managed well, and the samples and testing devices should be handled according to the prescribed procedures.
Storage Temp. Unopened kit, stored at 4 °C, shelf life 6 months.
Test Range 0.78-50ug/mL
Applications Whole blood