Product Details
Product Details
Product Specification
| protein | VEGF | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Usage |
1. You need to bring your own test equipment 1 Microplate reader (measurable) 450nm The absorption value of the detection wavelength and 540nm or 570nm (Absorption value of corrected wavelength) 2 High-precision liquid dispenser and disposable suction tip 3 Distilled water or deionized water 4 Bottle washer (spray bottle), multi-channel plate washer or automatic plate washer 5 、 500mL measuring cylinder II. Pre-experimental preparation 1 Sample collection and storage ( 1 ) Cell Culture Supernatant: Particulate matter should be removed by centrifugation; Test the sample immediately. If the sample is not tested in time after collection, it is recommended to repackage it according to the single-use amount and freeze it. -20℃ Inside the refrigerator, avoid repeated freezing and thawing. Samples may require diluent ( 1× Dilute. ( 2 ) Serum: Use serum separation tubes ( SST Collect samples and let them sit at room temperature. 30 minutes. centrifuge 15 Minutes, rotation speed 1000g 。 Serum was removed immediately and tested immediately. If the sample is not tested in time after collection, it is recommended to repackage it according to the single-use amount and freeze it. ≤-20℃ Inside the refrigerator, avoid repeated freezing and thawing. Samples may require diluent ( 1× Dilute. ( 3 ) Plasma: Use EDTA Heparin or citric acid are used as anticoagulants to collect plasma. After collection... 30 Centrifuge within minutes 15 Minutes, rotation speed 1000g And test immediately. If the sample is not tested in time after collection, it is recommended to repackage it according to the single-use amount and freeze it. ≤-20℃ Inside the refrigerator, avoid repeated freezing and thawing. Samples may require diluent ( 1× Dilute. 2 Reagent preparation ( Please allow all reagents and samples to stand at room temperature before use. 15 minutes. All experimental samples and standards are recommended. Perform multiple hole testing ) ( 1 ) 1× Washing solution preparation: The concentrated washing solution in the kit is 20× The mother liquor must be diluted with distilled water before use. 1× Working fluid. Example: take 10mL concentrated washing liquid +190mL Distilled water is set to 200mL In actual operation, the usage can be calculated first, and then the preparation can be carried out. ( 2 ) 1× Dilution buffer preparation: The concentrated dilution buffer in the kit is 10× The mother liquor must be diluted with distilled water before use. 1× Working fluid. Example: take 3mL Buffer for concentration and dilution +27mL Distilled water is set to 30mL 。 In actual operation, the required amount of dilution buffer can be calculated based on the sample dilution factor before preparation. ( 3 To detect antibodies: Centrifuge the dry powder to the bottom of the tube and use... 110μL Dilution buffer ( 1× Dissolve and let stand at room temperature. 5 Get it in minutes 100× mother liquor; Dilute before use 1× Working fluid. According to the dosage per well 100μL Calculate the required volume. Example: Used 10 Each hole, then take 10μL of 100 The working concentration of the detection antibody was determined using dilution buffer ( 1× ) Set the volume to 1mL , get 1mL of 1× Detection antibody at working concentration. ( 4 ) SA-HRP : SA-HRP For 40× Mother liquor, dilution buffer must be used before use ( 1× Dilute and prepare 1× Working fluid, the amount required per well is 100μL 。 Example: Used 10 Each hole, then take 25μL of 40× mother liquor +975μL Dilution buffer ( 1× ) Set the volume to 1mL , get 1mL of 1× Detection antibody at working concentration. ( 5 Color developer: per well 100μL Calculate the dosage required for the current test, take out the corresponding volume of color developer, and protect it from light; The removed color developer is for same day use only. ( 6 ) Standard: Dilution buffer for lyophilized standard ( 1× Resolution, resolution volume 1000μL The resulting concentration is 2000pg/mL Standard mother liquor. Gently shake at least 5 Minutes, it fully dissolves. Add to each dilution tube 300μL Dilution buffer ( 1× )。 Make serial dilutions of the standard mother liquor according to the figure below. Each tube must be thoroughly mixed before pipetting to the next tube. The undiluted standard stock solution can be used as the highest point of the standard curve ( 2000pg/mL ), dilution buffer ( 1× ) can be used as the zero point of the standard curve ( 0pg/mL )。 ![]() 1 Prepare all necessary reagents and standards; 2 Remove the microwell plate from the sealed bag that has been equilibrated to room temperature. Put the unused strip back into the aluminum foil bag and reseal it. 3 Add to the microplate 300μL Washing liquid, let stand and soak. 30 Seconds, discard the lotion and pat the microplate dry on absorbent paper. Use immediately. Do not let the microplate dry. 4 Add standards, experimental samples, or quality controls of different concentrations to the corresponding wells, and each well... 100μL 。 Seal the reaction wells with sealing tape and incubate at room temperature. 2 hour ; 5 Remove the liquid from the plate and wash the plate using a bottle washer, a multi-channel plate washer, or an automatic plate washing machine. Add washing liquid to each well 300μL Then, the washing liquid in the plate is sucked away. repetitive operation 3 Next. Removing as much residual liquid as possible during each plate wash will help obtain good experimental results. After the last washing of the plate, please dry all the liquid inside the plate or turn the plate upside down and pat dry any remaining liquid on absorbent paper; 6 Add into each microwell 100μL Antibodies are detected. Seal the reaction wells with sealing tape and incubate at room temperature. 2 hours; 7 Repeat the first 5 Step-by-step washing plate operation 8 Add into each microwell 100μL SA-HRP Incubation at room temperature 20 minutes. Pay attention to avoiding light; 9 Repeat the first 5 Step-by-step washing plate operation 10 Add into each microwell 100μL Chromogenic solution, incubated at room temperature 5-30 Minutes, take care to protect from light; 11 Add into each microwell 50μL Stop solution, the color of the solution in the well will change from blue to yellow. If the solution turns green or the color changes inconsistently, gently tap the microplate to mix the solution evenly; 12 After adding the stopping solution 30 Within minutes, measure using a microplate reader. 450nm Set the absorbance value. 540nm or 570nm As a correction wavelength. If dual wavelength correction is not used, the accuracy of the results may be affected; 13 Calculation results: Calculate the corrected absorbance values of each standard and sample. (OD450-OD540 or OD570) Take the average of the duplicate well readings, and then subtract the average zero standard. OD Value. Four-parameter logic using computer software (4-PL) Curve fitting creates a standard curve. Another method is to plot the standard concentration logarithmically against the corresponding OD Logarithmic curves were generated, and the best fit line was determined by regression analysis. This process produces a sufficiently useful, but not very accurate, data fit. If the sample is diluted, the concentration should be calculated by multiplying by the dilution factor. ![]() IV. Kit Parameters 1 Recovery rate: Different levels of cell culture medium were incorporated into the sample. Human VEGF , The recovery was determined. The recovery range is 113-135% The average recovery rate is 121% 。 2 Sensitivity: Human VEGF The lowest measurable dose ( MDD Generally in 7.8pg/mL 。 The lowest measurable value is based on 20 The corresponding concentration is calculated by adding the average of the zero-point absorbance values of each standard curve to twice the standard deviation. 3 Correction: This ELISA The kit was sf-21 High Purity Recombinant Expressed by Insect Cells Human VEGF Corrected by protein. 4 Linearity: 4 High concentrations were added to different samples. Human VEGF Then use diluent ( 1× ) Dilute the sample within the test range and determine its linearity.
5 Specificity: This ELISA The method can detect both natural and recombinant substances. Human VEGF Protein. The following factors are mixed with diluent ( 1× ) configured to 50ng/mL Concentration to detect and Human VEGF Cross-reaction. will 50ng/mL The incorporation of interfering factors into the recombination of the intermediate range Human VEGF In the reference substance, to detect the Human VEGF Interference. No significant cross-reactions or interferences were observed. containing concentration 3125pg/mL restructuring Human VEGF165/PlGF Heterodimers have 23% Cross-reactivity, with concentration 312.5pg/mL of recombinant dog VEGF have 41.2% Cross-reactivity, recombinant Human VEGF R1( Flt- 1)/Fc chimera and rhVEGF R2 (KDR)/Fc Embedded The combination is at a concentration of >781 pg/mL and 12.5 ng/mL Interference occurred.
V. Analysis of Frequently Asked Questions 1 Whiteboard (no color appears after color development)
2 Flower plate (blank, negative and positive controls are normal, but specimen holes OD (The value is significantly high)
VI. Experimental Flowchart ![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Sensitivity | 7.8pg/mL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Species Reactivity | Human | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Theory | This kit adopts double antibody sandwich enzyme-linked immunosorbent detection technology. Specific anti-human VEGF antibodies were pre-coated on high affinity enzyme label plates. The standard, the sample to be tested, and the biotinylated detection antibody are added to the well of the enzyme labeled plate. After incubation, the VEGF present in the sample binds to the solid antibody and the detection antibody to form an immune complex. After washing to remove unbound material, horseradish peroxidase-labeled Streptavidin (Streptavidin-HRP) was added. After washing, a chromogenic substrate was added and the color was developed in the dark. A stop solution was added to stop the reaction, and the absorbance value was measured at a wavelength of 450 nm (reference correction wavelength of 540 nm or 570 nm). | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Synonym | MVCD1, VAS, vascular endothelial growth factor A, Vascular permeability factor, Vasculotropin, VEGF, VEGFA, VEGF-A, VEGFMGC70609, VPF, VPFvascular endothelial growth factor | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Wells | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Composition |
Please use the kit within its expiration date.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Background | Vascular endothelial growth factor ( VEGF or VEGF-A Also known as vascular permeability factor, it is an effective regulator of angiogenesis and angiogenesis in fetuses and adults. Vascular endothelial growth factor belongs to PDGF This family of proteins is characterized by the presence of proteins at the cystine junction and the structure of dimers bound by reverse parallel disulfide bonds. 8 A conserved cystine residue. Through selective cleavage and sequence length of amino acids, humans express different subtypes including: VEGF121 、 VEGF145 、 VEGF165 、 VEGF183 、 VEGF189 and VEGF206 etc. among VEGF165 It is the subtype with the highest expression rate, followed by VEGF121 and VEGF189 。 Besides VEGF121 The other subtypes contain a basic heparin-binding region and cannot diffuse freely. human VEGF165 The corresponding protein amino acid sequence homology with mice and rats is 88% 。 VEGF Expressed in various cells and tissues, including skeletal and cardiomyocytes, hepatocytes, osteoblasts, neutrophils, macrophages, keratinocytes, brown adipocytes, CD34+ stem cells, endothelial cells, fibroblasts, vascular smooth muscle cells, and the like. VEGF Expression is induced by hypoxia and cytokines, including IL-1 、 IL-6 、 IL-8 Tumor suppressor M and tumor necrosis factor α etc. During development and in adulthood, VEGF The expression levels are also different. VEGF dimer and 2 Combined with related tyrosine kinase receptors, i.e. VEGFR1 (Also called Flt-1 ) and VEGFR2 ( Flk-1/KDR )。 VEGF At the same time, homodimerization and autophosphorylation processes of the latter can be induced. These receptors possess 7 There are two extracellular immunoglobulin domains and one intracellular separate tyrosine receptor domain. Both vascular endothelial cells and some other non-endothelial cells express VEGF Receptor. Although VEGF with VEGFR1 The most affinity, but VEGFR2 But it is regulation VEGF The main factor of angiogenesis. VEGF165 It also binds to brachial plate protein ( semaporin ) receptor, neuropilin 1 ( Neuropilin-1 ), thereby promoting VEGFR2 The complex is formed. VEGF It is known for its involvement in angiogenesis. During embryonic development, VEGF Regulating the proliferation, migration and survival of endothelial cells, and thereby regulating the density and volume of blood vessels; However, it does not work on the pattern of angiogenesis. VEGF It promotes bone formation through the recruitment of osteoblasts and chondrocytes, and it is also a monocyte chemokine. After childbirth, VEGF It maintains the integrity of vascular endothelial cells and is a major... / Effective mitogens of small vascular endothelial cells. In adults, VEGF It mainly plays a role in wound repair and the female reproductive cycle. In disease organizations, VEGF Promote vascular permeability. Therefore, VEGF It participates in the metastatic process of tumors through extravasation and tumor angiogenesis. Against blocking VEGF Various active therapeutic strategies are Used to control by VEGF Induced tumor angiogenesis. circulating in the body VEGF The levels correlate with the extent of the condition of autoimmune diseases (such as rheumatoid arthritis, multiple sclerosis, systemic lupus erythematosus, etc.). |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| General Notes | 1. Please use the kit within its expiration date. 2. Components of different reagent kits and reagent kits with different batch numbers cannot be mixed. 3. If the sample value is greater than the highest value of the standard curve, the sample should be diluted with diluent (1×) and then retested; If the cell culture supernatant sample requires distribution dilution, cell culture medium can be used for other intermediate dilutions except for the final dilution with diluent. 4. Differences in test results can be caused by a variety of factors, including the operation of the experimenter, the way the pipette is used, the plate washing technique, the reaction time or temperature, and the storage of the reagent kit. 5. The termination solution in the kit is an acidic solution. Please take good care of your glasses, hands, face and clothing when using it. 6. For scientific research only, not for in vitro diagnosis. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Storage Temp. | Store unopened kit at 2-8°C. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Test Range | 31.3pg/mL-2000pg/mL |
Picture
Picture
Immunohistochemistry
.jpg)