Product Details
Product Details
Product Specification
| protein | IL-6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| WGK Germany | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Usage |
I. Own test equipment is required: 1 Microplate reader (measurable) 450nm The absorption value of the detection wavelength and 540nm or 570nm (Absorption value of corrected wavelength) 2 High-precision liquid dispenser and disposable suction tip 3 Distilled water or deionized water 4 Bottle washer (spray bottle), multi-channel plate washer or automatic plate washer 5 、 500mL measuring cylinder II. Pre-experimental preparation: 1 Sample collection and storage ( 1 ) Cell Culture Supernatant: Particulate matter should be removed by centrifugation; Test the sample immediately. If the sample is not tested in time after collection, it is recommended to repackage it according to the single-use amount and freeze it. -20℃ Inside the refrigerator, avoid repeated freezing and thawing. Samples may require diluent ( 1× Dilute. ( 2 ) Serum: Use serum separation tubes ( SST Collect samples and let them sit at room temperature. 30 minutes. centrifuge 15 Minutes, rotation speed 1000g 。 Serum was removed immediately and tested immediately. If the sample is not tested in time after collection, it is recommended to repackage it according to the single-use amount and freeze it. ≤-20℃ Inside the refrigerator, avoid repeated freezing and thawing. Samples may require diluent ( 1× Dilute. ( 3 ) Plasma: Use EDTA Heparin or citric acid are used as anticoagulants to collect plasma. After collection... 30 Centrifuge within minutes 15 Minutes, rotation speed 1000g And test immediately. If the sample is not tested in time after collection, it is recommended to repackage it according to the single-use amount and freeze it. ≤-20℃ Inside the refrigerator, avoid repeated freezing and thawing. Samples may require diluent ( 1× Dilute. 2 Reagent preparation ( Please allow all reagents and samples to stand at room temperature before use. 15 minutes. All experimental samples and standards are recommended. Perform multiple hole testing ) ( 1 ) 1× Washing solution preparation: The concentrated washing solution in the kit is 20× The mother liquor must be diluted with distilled water before use. 1× Working fluid. Example: take 10mL concentrated washing liquid +190mL Distilled water is set to 200mL In actual operation, the usage can be calculated first, and then the preparation can be carried out. ( 2 ) 1× Dilution buffer preparation: The concentrated dilution buffer in the kit is 10× The mother liquor must be diluted with distilled water before use. 1× Working fluid. Example: take 3mL Buffer for concentration and dilution +27mL Distilled water is set to 30mL 。 In actual operation, the required amount of dilution buffer can be calculated based on the sample dilution factor before preparation. ( 3 To detect antibodies: Centrifuge the dry powder to the bottom of the tube and use... 110μL Dilution buffer ( 1× Dissolve and let stand at room temperature. 5 Get it in minutes 100× mother liquor; Dilute before use 1× Working fluid. According to the dosage per well 100μL Calculate the required volume. Example: Used 10 Each hole, then take 10μL of 100 The working concentration of the detection antibody was determined using dilution buffer ( 1× ) Set the volume to 1mL , get 1mL of 1× Detection antibody at working concentration. ( 4 ) SA-HRP : SA-HRP For 40× Mother liquor, dilution buffer must be used before use ( 1× Dilute and prepare 1× Working fluid, the amount required per well is 100μL 。 Example: Used 10 Each hole, then take 25μL of 40× mother liquor +975μL Dilution buffer ( 1× ) Set the volume to 1mL , get 1mL of 1× Detection antibody at working concentration. ( 5 Color developer: per well 100μL Calculate the dosage required for the current test, take out the corresponding volume of color developer, and protect it from light; The removed color developer is for same day use only. ( 6 ) Standard: Dilution buffer for lyophilized standard ( 1× Resolution, resolution volume 1000μL The resulting concentration is 600pg/mL Standard mother liquor. Gently shake at least 5 Minutes, it fully dissolves. Add to each dilution tube 300μL Dilution buffer ( 1× )。 Make serial dilutions of the standard mother liquor according to the figure below. Each tube must be thoroughly mixed before pipetting to the next tube. The undiluted standard stock solution can be used as the highest point of the standard curve ( 600pg/mL ), dilution buffer ( 1× ) can be used as the zero point of the standard curve ( 0pg/mL )。 ![]() 1 Prepare all necessary reagents and standards; 2 Remove the microwell plate from the sealed bag that has been equilibrated to room temperature. Put the unused strip back into the aluminum foil bag and reseal it. 3 Add to the microplate 300μL Washing liquid, let stand and soak. 30 Seconds, discard the lotion and pat the microplate dry on absorbent paper. Use immediately. Do not let the microplate dry. 4 Add standards, experimental samples, or quality controls of different concentrations to the corresponding wells, and each well... 100μL 。 Seal the reaction wells with sealing tape and incubate at room temperature. 2 hour ; 5 Remove the liquid from the plate and wash the plate using a bottle washer, a multi-channel plate washer, or an automatic plate washing machine. Add washing liquid to each well 300μL Then, the washing liquid in the plate is sucked away. repetitive operation 3 Next. Removing as much residual liquid as possible during each plate wash will help obtain good experimental results. After the last washing of the plate, please dry all the liquid inside the plate or turn the plate upside down and pat dry any remaining liquid on absorbent paper; 6 Add into each microwell 100μL Antibodies are detected. Seal the reaction wells with sealing tape and incubate at room temperature. 2 hours; 7 Repeat the first 5 Step-by-step washing plate operation 8 Add into each microwell 100μL SA-HRP Incubation at room temperature 20 minutes. Pay attention to avoiding light; 9 Repeat the first 5 Step-by-step washing plate operation 10 Add into each microwell 100μL Chromogenic solution, incubated at room temperature 5-30 Minutes, take care to protect from light; 11 Add into each microwell 50μL Stop solution, the color of the solution in the well will change from blue to yellow. If the solution turns green or the color changes inconsistently, gently tap the microplate to mix the solution evenly; 12 After adding the stopping solution 30 Within minutes, measure using a microplate reader. 450nm Set the absorbance value. 570nm or 630nm As a correction wavelength. If dual wavelength correction is not used, the accuracy of the results may be affected; 13 Calculation results: Calculate the corrected absorbance values of each standard and sample. (OD450-OD540 or OD570) Take the average of the duplicate well readings, and then subtract the average zero standard. OD Value. Four-parameter logic using computer software (4-PL) Curve fitting creates a standard curve. Another method is to plot the standard concentration logarithmically against the corresponding OD Logarithmic curves were generated, and the best fit line was determined by regression analysis. This process produces a sufficiently useful, but not very accurate, data fit. If the sample is diluted, the concentration should be calculated by multiplying by the dilution factor. ![]() IV. Kit parameters: 1 Recovery rate: Different levels of cell culture medium were incorporated into the sample. Human IL-6 The recovery rate is determined. The recovery range is 93-101% The average recovery rate is 98% 。 2 Sensitivity: Human IL-6 The lowest measurable dose ( MDD ) is generally less than 1.56pg/mL 。 The lowest measurable value is based on 20 The corresponding concentration is calculated by adding the average of the zero-point absorbance values of each standard curve to twice the standard deviation. 3 Linearity: 4 High concentrations were added to different samples. Human IL-6 Then use diluent ( 1× ) Dilute the sample within the test range and determine its linearity.
4 Specificity: This ELISA The method can detect both natural and recombinant substances. Human IL-6 Protein. The following factors are mixed with diluent ( 1× ) Prepared 50ng/mL Concentration to detect and Human IL-6 Cross-reaction. will 50ng/mL The incorporation of interfering factors into the recombination of the intermediate range Human IL-6 In the reference substance, to detect the Human IL-6 Interference. No significant cross-reactions or interferences were observed.
V. Analysis of Frequently Asked Questions 1 Whiteboard (no color appears after color development)
VI. Experimental flowchart: ![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Beilstein | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Sensitivity | 1.56pg/mL | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Species Reactivity | Human | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Theory | This kit adopts double antibody sandwich enzyme-linked immunosorbent detection technology. Specific anti-human IL-6 antibodies are pre-coated on high affinity enzyme label plates. The standard, the sample to be tested, and the biotinylated detection antibody are added to the well of the enzyme labeled plate. After incubation, the IL-6 present in the sample binds to the solid-phase antibody and the detection antibody to form an immune complex. After washing to remove unbound material, horseradish peroxidase-labeled Streptavidin (Streptavidin-HRP) was added. After washing, a chromogenic substrate was added and the color was developed in the dark. A stop solution was added to stop the reaction, and the absorbance value was measured at a wavelength of 450 nm (reference correction wavelength of 540 nm or 570 nm). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Source | Human | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Synonym | B cell stimulatory factor-2, B-cell differentiation factor, BSF-2, BSF2CTL differentiation factor, CDF, HGFHSFIFNB2Hybridoma growth factor, IFN-beta-2, IL6, IL-6, IL-6B-cell stimulatory factor 2, interferon beta-2, interleukin 6 (interferon, beta 2), interleukin BSF-2, interleukin-6, MGI-2A, Human Interleukin 6 ELISA Kit | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PubChem CID | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Wells | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Composition |
Please use the kit within its expiration date (new and old products will be shipped randomly).
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Background | Interleukin -6 ( IL-6 ) is a α helical structure, 22-28kDa A multifunctional cytokine with varying degrees of phosphorylation and glycosylation, it plays an important role in acute disease response, inflammation, hematopoiesis, bone metabolism, and cancer progression. Mature people IL-6 have 183 Amino acids, with mice and rats IL-6 have 41% Homology. IL-6 Internal alternative splicing produces a variety of isomers, some of which exhibit antagonistic properties. known expression IL-6 The cells include CD8+T cells, fibroblasts, synovial cells, adipocytes, osteoblasts, megakaryocytes, endothelial cells (under the influence of endothelin), sympathetic neurons, cerebral cortical neurons, adrenal medulla chromaffin cells, retinal pigment cells, mast cells, keratinocytes, Langerhans cells, fetal and adult glial cells, neutrophils, monocytes, eosinophils, colonic epithelial cells, B1B Cells and islets β Cells. IL-6 The production is usually under the control of glucocorticoids, catecholamines, and secondary steroids, and is generally associated with cell activation. In normal human blood IL-6 In 1pg/mL Within this range, there is a slight increase during menstruation, a severe increase in the middle and late stages of some cancers, and a significant increase after major surgery. IL-6 Cell signals are triggered by cell surface receptors, which are formed by ligand-binding subunits ( IL-6 Receptors) and signal transfer to subunits gp130 A heterodimeric complex of composition. IL-6 Combined with IL-6 On the receptor, it triggered IL-6 receptor and gp130 The combination and gp130 Dimerization. gp130 Also CLC 、 CNTF 、 CT-1 、 IL-11 、 IL-27 、 LIF and OSM A component of a receptor. soluble IL-6 Receptors are produced by alternative splicing and protease cleavage. Through the trans signaling mechanism, solubility IL-6 and IL-6 Receptor complexes can cause surface deficiencies IL-6 receptor but expression gp130 Cellular response. IL-6 Receptor expression is mainly limited to hepatocytes, monocytes, lymphocytes, and resting lymphocytes, due to gp130 Molecular expression is very broad, and transsignal transduction enables a wider range of cell types. IL-6 The response. soluble gp130 The spliceosome prevented IL-6/IL-6R Trans-signal transduction, but cannot prevent the use of other cytokines. gp130 Signal transduction of molecules as co-receptors. IL-6 With tumor necrosis factor α ( TNFα ) and IL-1 Firstly, the acute inflammatory response caused plays an almost unique role in fever and acute inflammatory responses in the liver, and it also plays an important role in the transformation of acute inflammation into acquired immune or chronic inflammatory diseases. IL-6 Disorders can promote chronic inflammation, such as obesity, insulin resistance, inflammatory bowel disease, inflammatory arthritis, and sepsis, often involving IL-6 Trans-signal transduction. In transforming growth factors TGF-β Under existing conditions, IL-6 In the naive type T cell to Th17 It plays an important role in the process of inflammatory cell differentiation. IL-6 Regulates bone resorption, and by promoting Th17 The activity of inflammatory cells has become the main factor causing inflammatory joint damage in rheumatoid arthritis. IL-6 Involved in the formation and instability of atherosclerotic plaques. However, IL-6 It also has anti-inflammatory effects, such as skeletal muscle secretion during physical exercise. IL-6 。 It acts as a growth factor to promote and induce hematopoietic stem cells. B Cell maturation is the immortality of plasma cells and multiple myeloma cells. IL-6 It also promotes, but may not initiate, other inflammation-related cancer development, such as colitis-related cancer. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| General Notes | 1. Please use the kit within its expiration date. 2. Components of different reagent kits and reagent kits with different batch numbers cannot be mixed. 3. If the sample value is greater than the highest value of the standard curve, the sample should be diluted with diluent (1×) and then retested; If the cell culture supernatant sample requires distribution dilution, cell culture medium can be used for other intermediate dilutions except for the final dilution with diluent (1×). 4. Differences in test results can be caused by a variety of factors, including the operation of the experimenter, the way the pipette is used, the plate washing technique, the reaction time or temperature, and the storage of the reagent kit. 5. The termination solution in the kit is an acidic solution. Please take good care of your glasses, hands, face and clothing when using it. 6. For scientific research only, not for in vitro diagnosis. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Storage Temp. | Store unopened kit at 2-8°C. Shelf life is 12 months. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Test Range | 9.38pg/mL-600pg/mL |
Picture
Picture
Immunohistochemistry
.jpg)