Product Details
Product Details
Product Specification
| protein | FSH | |||||||||||||||||||||||||||||||||
| Usage |
I. Self-provided test equipment required for the experiment: 1. Microplate reader (450nm) 2. High-precision sampler and gun tip: 0.5-10μL, 5-50μL, 20-200μL, 200-1000μL 3. 37℃ constant temperature oven 4. Distilled water or deionized water II. Sample handling and requirements: The detection range of the kit is not equivalent to the concentration range of the substance to be tested in the sample. It is recommended to estimate the concentration of the substance to be tested in the sample through relevant literature before the experiment and determine the actual concentration of the sample through pre-experiments. If the concentration of the test substance in the sample is too high or too low, dilute or concentrate the sample appropriately. If the tested sample is not among the sample types listed in the instructions, it is recommended to conduct a preliminary experiment to verify its detection effectiveness. Serum:Whole blood samples collected in serum separation tubes should be placed at room temperature for 2 hours or 2-8°C overnight, then centrifuged at 1000×g for 20 minutes to collect the supernatant, or the supernatant should be stored at -20°C or -80°C, but repeated freezing and thawing should be avoided. Plasma:Collect samples using EDTA or heparin as anticoagulants, and centrifuge the samples at 2-8℃ 1000×g for 15 minutes within 30 minutes after collection. Take the supernatant for detection, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. Tissue homogenate:Rinse the tissue with pre-cooled PBS (0.01M, pH=7.4) to remove residual blood (lysed red blood cells in the homogenate can affect the test results), weigh and shear the tissue. Add the shredded tissue and the corresponding volume of PBS (generally according to a weight-to-volume ratio of 1:9, for example, 1g of tissue sample corresponds to 9mL of PBS, the specific volume can be appropriately adjusted according to experimental needs, and record it. It is recommended to add a protease inhibitor to the PBS) into a glass homogenizer, and grind thoroughly on ice or in a homogenizer. To further lyse tissue cells, the homogenate can be sonicated or repeatedly freeze-thawed. Finally, the homogenate was centrifuged at 5000×g for 5-10 minutes, and the supernatant was taken for detection. Cell culture supernatant:Centrifuge 1000×g for 20 minutes and collect the supernatant for detection, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing. Cell lysate:Adherent cells were gently washed with pre-cooled PBS, then digested with trypsin, centrifuged at 1000×g for 5 minutes, and collected; Suspension cells can be collected directly by centrifugation. Collected cells were washed three times with pre-cooled PBS, resuspended with 150-200 μl of PBS added per 1 x 106 cell (protease inhibitor added to PBS is recommended; PBS volume may be appropriately reduced if the content is low) and disrupted by repeated freeze-thaw or sonication. Centrifuge the extract at 2-8℃ at 1500×g for 10 minutes, and take the supernatant for detection. Other biological samples:Centrifuge 1000×g for 20 minutes, and take the supernatant for detection. Sample appearance:The sample should be clear and transparent, and suspended matter should be removed by centrifugation. Sample storage:If samples are collected and tested within 1 week, they can be stored at 4℃. If they cannot be tested in time, please repackage them according to the single-use amount and freeze them at -20℃ (tested within 1 month) or -80℃ (tested within 6 months). Avoid repeated freezing and thawing, as sample hemolysis will affect the final test results. Therefore, hemolyzed samples should not be tested. III. Sample dilution scheme: Please estimate the concentration range of the sample in advance. If your test sample needs to be diluted, the reference dilution scheme is as follows: Dilute 100 times:One-step dilution. Take 5μL of the sample into 495μL of universal diluent and dilute it 100 times; Dilute 1000 times:Two-step dilution. Take 5 μl of the sample into 95 μl of universal diluent and dilute it 20 times, then take 5 μl of the 20-fold diluted sample into 245 μl of universal diluent and dilute it 50 times, for a total of 1000 times; Dilute 100000 times:Three-step dilution. Take 5 μl of the sample into 195 μl of universal diluent, dilute 40 times, then take 5 μl of the 40-fold dilution sample into 245 μl of universal diluent, dilute 50 times, and finally take 5 μl of the 2000-fold dilution sample into 245 μl of universal diluent, dilute 50 times, for a total dilution of 100,000 times; The amount of liquid taken during each dilution step shall not be less than 3 μL, and the dilution factor shall not exceed 100 times. Each dilution step should be mixed evenly to avoid foaming. IV. Pre-test preparations: 1. Please remove the reagent kit from the refrigerator 10 minutes in advance and allow it to equilibrate to room temperature. 2. Preparation of standard gradient working solution:Add 1mL of general diluent to the lyophilized standard, let it stand for 15 minutes until it is completely dissolved, then mix gently (concentration is 10mIU/mL), and then dilute according to the following concentrations: 10mIU/mL, 5mIU/mL, 2.5mIU/mL, 1.25mIU/mL, 0.625mIU/mL, 0.312mIU/mL, 0.156mIU/mL, 0mIU/mL. Ratio dilution method: Take 7 EP tubes, add 500μL of general diluent to each tube, draw 500μL of 10mIU/mL standard working solution into the first EP tube and mix well to prepare 5mIU/mL standard working solution, and then draw and mix well according to this step. The last tube is directly used as a blank hole, so there is no need to draw liquid from the penultimate tube, as shown in the figure below. ![]() 4. Preparation of enzyme conjugate working solution:Centrifuge 100× concentrated enzyme conjugate at 1000×g for 1 minute 15 minutes before use, dilute 100× concentrated enzyme conjugate to 1× working concentration with universal diluent (e.g., 10 μL concentrate + 990 μL universal diluent), and prepare ready for use. 5.1× Washing Solution Preparation:Take 10ml of 20× washing solution into 190mL of distilled water (the concentrated washing solution taken out of the refrigerator may have crystals, which is a normal phenomenon. It can be placed at room temperature until the crystals are completely dissolved before preparation). V. Operating Steps: 1. Remove the required strips from the aluminum foil bag after equilibrating at room temperature for 10 minutes. Seal the remaining strips with a self-sealing bag and place them back at 4℃. 2. Add samples: Add 100μL of samples or standards of different concentrations to the corresponding wells, and add 100μL of general diluent to the blank wells. The plate was covered with a sealing film and incubated at 37° C. for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1 times with a general diluent before adding it to the enzyme label plate for testing. This will reduce the impact of matrix effects on the test results. Finally, when calculating the sample concentration, multiply by the corresponding dilution factor. It is recommended to set up replicate wells for all samples to be tested and standards during testing). 3. Add biotinylation to detect resistance: Remove the enzyme label plate, discard the liquid, and do not wash. Add 100 μl of biotinylated antibody detection working solution directly to each well, cover with plate sealing film and incubate at 37℃ for 60 minutes. 4. Washing the plate: Discard the liquid, add 300μL of 1X washing solution to each well, let it stand for 1 minute, then remove the washing solution and pat dry on absorbent paper. Repeat washing the plate 3 times (you can also wash the plate with a plate washer). 5. Add enzyme conjugate working solution: Add 100 μL of enzyme conjugate working solution to each well, cover with a sealing film, and incubate at 37℃ for 30 minutes. 6. Washing the plate: Discard the liquid and wash the plate 5 times according to the washing method in step 4. 7. Add substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C for 15 minutes in the dark. 8. Add stop solution: Remove the enzyme label plate, add 50μL of stop solution directly to each well, and immediately measure the OD value of each well at a wavelength of 450nm. VI. Calculation of experimental results: Judgment of results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as the correction value. With concentration as the abscissa and OD value as the ordinate, plot the standard curve of the four-parameter logistic function on double-logarithmic coordinate paper. 2. If the OD value of the sample is higher than the upper limit of the standard curve, it should be diluted appropriately before retesting and multiplied by the corresponding dilution factor when calculating the sample concentration. VII. Kit Performance:1. Repeatability: The intra-plate coefficient of variation is less than 10%, and the inter-plate coefficient of variation is less than 10%. 2. Recovery: Three different concentrations of human FSH were added to selected healthy human serum, plasma, and cell culture supernatant to calculate the recovery rate.
3. Linear dilution: Add high-concentration human FSH to 4 selected healthy human serum, plasma and cell culture supernatants, and dilute them within the kinetic range of the standard curve to evaluate linearity.
|
|||||||||||||||||||||||||||||||||
| Sensitivity | 0.076mIU/mL | |||||||||||||||||||||||||||||||||
| Species Reactivity | Human | |||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Into microwells previously coated with human follicle stimulating hormone (FSH) capture antibodies, samples, standards, biotin-labeled detection antibodies, and HRPase conjugates were added in sequence, followed by incubation and washing, and developed with the substrate TMB. TMB was converted to blue under the catalysis of peroxidase (HRP) and finally to yellow under the action of acid. The depth of color was positively correlated with human follicle stimulating hormone (FSH) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the sample concentration was calculated. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Follicle Stimulating Hormone ELISA Kit | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | 卵泡刺激素(FSH)是一种促性腺激素,也是一种糖蛋白多肽激素。FSH由垂体前叶的促性腺激素细胞合成和分泌,它和黄体生成素(LH)在生殖系统中共同发挥作用。FSH是一个35.5kDa的糖蛋白异构体,由两个多肽单元组成,即α和β。其结构与黄体生成素(LH)、促甲状腺激素(TSH)和人绒毛膜促性腺激素(hCG)的结构相似。 | |||||||||||||||||||||||||||||||||
| General Notes | 1. Incubate strictly according to the specified time and temperature to ensure accurate results. All reagents must reach room temperature of 20-25℃ before use. Refrigerate the reagents immediately after use. 2. Incorrect plate washing may lead to inaccurate results. Ensure that the fluid in the wells is sucked dry as much as possible before adding the substrate. Do not allow the microwells to dry for too long during the entire process. 3. Clean any remaining liquid and fingerprints from the bottom of the plate, otherwise it will affect the OD value. 4. The substrate developing solution should be colorless; substrate solutions that have turned blue should not be used. 5. Avoid cross-contamination of reagents and samples to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. No reactant should come into contact with the bleaching solvent or the strong gases emitted by the bleaching solvent. Any bleaching ingredient will destroy the biological activity of the reagents in the kit. 8. Expired products must not be used, and ingredients with different product numbers and batch numbers must not be mixed. 9. Recombinant proteins from sources other than the kit may not match the antibodies in this kit and may not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly, and the samples and testing devices should be handled according to the prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | 未开封试剂,2-8℃储存,有效期6个月。 |
|||||||||||||||||||||||||||||||||
| Test Range | 0.156-10mIU/mL |
Picture
Picture
Immunohistochemistry
.jpg)


VII. Kit Performance: