Skip to product information
1 of 1

Human Fc quantification kit - human Fc定量试剂盒

Human Fc quantification kit - human Fc定量试剂盒

Catalog Number: UA085005 Brand: UA BIOSCIENCE
Price:
Regular price $300 USD
Regular price Sale price $300 USD
Size:

For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification


Host Human
Stability & Storage

-80℃

Background

This kit employs homogeneous time-resolved fluorescence technology and can be used to detect Human IgG antibodies in cell culture supernatants. The kit includes an antibody-labeled donor Eu (anti-Human IgG-Eu) and a Human IgG-labeled acceptor (Human IgG-Ac). The anti-Human IgG-Eu binds to Human IgG-Ac, and when excited by 320 nm light, the donor transfers energy to the acceptor, which then emits light at a specific wavelength (665 nm).

Human IgG antibodies in the sample competitively bind to anti-Human IgG-Eu, resulting in a signal inversely proportional to the concentration of Human IgG in the standard. This allows quantification of Human IgG in the sample based on a standard curve. This homogeneous assay requires no washing and enables accurate quantification of total Human IgG.

Components

Component

Concentration

100T

500T

2500T

10000T

Storage Temperature

Anti-Human IgG-Eu*

50×

10μL

50μL

250μL

1000μL

-80℃

Human IgG-Ac*

50×

10μL

50μL

250μL

1000μL

-80℃

IgG Standard

1mg/ml

5μL

10μL

50μL

200μL

-80℃

Assay Buffer

1.5mL

6ml

30mL

120mL

-80℃

Standard Diluent

1.5mL

6ml

30mL

120mL

-80℃


Note: Aliquot immediately after first thaw and store at recommended temperatures. Avoid storage after dilution or repeated freeze-thaw cycles.

Protocol

1. Reagent Preparation

Thaw all reagents at room temperature before use (equilibrate at room temperature for at least 30 min). The reaction volume for the 384-well shallow plate is 20 μL (reagent volumes for the reaction system are shown in Table 2). Calculate the required volume for the experiment before preparation and prepare as needed; the following preparation is for reference only, using 500 assays as an example.

Table 1. Reagent Preparation

Reagent Name

Preparation

Volume per Assay Well (μL)

Anti-Human IgG-Eu

Add 2450 μL Detection Buffer to 50 μL Anti-Human IgG-Eu, mix well, and keep on standby.

5

Human IgG-Ac

Add 2450 μL Detection Buffer to 50 μL Human IgG-Ac, mix well, and keep on standby.

5

IgG Standard

Take 10 μL of the standard stock solution, add 115 μL of standard diluent, mix thoroughly. Standard curve dilutions are as follows.

10


Table 2. Preparation of Standard Working Solutions

Standard Working Solution Concentration

(ng/mL)

Preparation Method

80000.0 10μL standard original stock solution + 115μL standard diluent

20000.0 20μL +60μL standard diluent

5000.0 20μL +60μL standard diluent

1250.0 20μL ③+60μL standard diluent

312.5 20μL ④+60μL standard diluent

78.125 20μL ⑤+60μL standard diluent

19.531 20μL ⑥+60μL standard diluent

4.88 20μL ⑦+60μL standard diluent

1.220 20μL ⑧+60μL standard diluent

0.305 20μL ⑨+60μL standard diluent

Blank

0.0 60μL standard diluent


2. Sample Addition and Controls

Order of sample addition: 10μL standard or sample; 5μL Anti-Human IgG-Eu; 5μL Human IgG-Ac are added sequentially to the 384-well shallow plate. (Note: Human IgG-Ac is added last)

NC: Replace 5μL Human IgG-Ac with 5μL Detection Buffer, and replace sample with 10μL standard diluent.

Maximum Control: Replace sample with 10μL standard diluent.

3.Detection

Seal the plate wells with a plate sealer, centrifuge at 1000 rpm for 1 min, and incubate at room temperature for 1 h. Detect on a TR-FRET compatible microplate reader (excitation wavelength 320 nm, emission wavelengths 620 nm and 665 nm).

[Result Calculation]

1. TR-FRET Ratio Calculation

TR-FRET Ratio = 665nm / 620nm *10000

2. Calculate CV (%)

CV(%)= Standard Deviation/Mean Ratio×100%

[Data Example]

Please note that the following data cannot replace the data obtained in experiments and is provided only as an example. Results may vary depending on the TR-FRET compatible instrument.

Std

Concentration (ng/mL)

Standard

Ratio

CV%

80000

163.65

7.65%

20000

255.25

0.86%

5000

467.2

0.29%

1250

1581

6.71%

312.5

3420.5

4.53%

78.125

3980.1

3.49%

19.531

3704.5

0.02%

4.883

3785.5

3.90%

1.221

3673.5

1.56%

0.305

3940.5

8.06%

Blank

0

3965

3.92%

NC

NC

121.75

5.52%