Enrich or deplete CD4+ T cells from human PBMCs. Stain CD4+ cells with anti-CD4 (clone: RPA-T4) Brilliant Violet 421™, and gate on the live cell population for analysis.
Product Details
Product Details
Product Specification
| Format | Dextran-coated iron tetroxide nanomagnetic beads coupled with an anti-human CD4 monoclonal antibody |
| Capacity |
2 mL magnetic beads: suitable for a total cell count of 1×10⁹, and can perform up to 100 separations 1 mL magnetic beads: suitable for 5×108total cells, and can perform up to 50 separations |
| Principle of Separation | CD4⁺ cells are magnetically labeled using CD4 Nanobeads for humans. The cell suspension is then loaded into a separation column placed within the sorter's magnetic field. The magnetically labeled CD4⁺ cells remain retained in the column, while the unlabeled cells flow through; this fraction constitutes the negative fraction after removal of CD4⁺ cells. After removing the separation column from the magnetic field, the magnetically captured CD4⁺ cells can be eluted, yielding the positive sorted fraction. If higher purity is required, the positive sorted fraction containing CD4⁺ cells must be further separated using a second column. |
| Reactivity | Human |
| Magnetic Bead Size | 20 nm |
| Separation Method | Column-Based |
| Selection Strategy | Positive Selection |
| Stability & Storage | Store protected from light at 2–8°C; do not freeze. |
Background
CD4 NanoBeads are designed to isolate human cells based on the expression of the CD4 antigen. CD4 is a 55 kDa protein that is highly expressed on helper T cells in the thymus and peripheral blood. In helper T cells, CD4 functions as a co-molecule, assisting the TCR heterodimer in recognizing MHC class II–peptide complexes. CD4 is also expressed on monocytes and dendritic cells, though at lower levels than in CD4+ helper T cells. When bound to certain chemokine receptors, CD4 serves as the primary high-affinity receptor for HIV.
Protocol
Taking S as an exampleSeparation ColumnFor instance
Steps |
Operating procedures |
Dosage / Time |
|
Magnetic labeling |
1 |
Count the total number of cells |
— |
2 |
Centrifuge the cell suspension at 400×g for 7 minutes, and completely discard the supernatant |
400×g, 7 min |
|
3 |
Resuspend every 1×10⁷ cells in 80 μL of buffer Note:Adjust the volume of the buffer proportionally according to the sample volume |
Resuspend the cells |
|
4 |
Add 20 μL of CD4 NanoBeads per 1×10⁷ cells Note:When the cell quantity increases, increase the volume of all reagents proportionally |
Add 20 μL per 1×10⁷ cells |
|
5 |
Mix thoroughly and incubate in the dark at 2–8℃ for 15 minutes |
Incubate for 15 minutes |
|
6 |
Wash every 1×10⁷ cells with 1 mL of buffer, centrifuge at 400×g for 7 minutes, and completely discard the supernatant. |
Add 1 mL to 1×10⁷ cells |
|
7 |
Resuspend up to 1×10 in 500 μL of buffer8Cells |
Resuspend cells |
|
Magnetic separation |
8 |
Place the S-type separation column into the magnetic field of the corresponding magnetic separator, and rinse the column with 500 μL of buffer. |
Rinse the separation column |
9 |
Load the cell suspension onto the separation column and collect the effluent (unlabeled cells). |
— |
|
10 |
Wash the column three times with 500 μL of buffer each time, adding the next wash only after the liquid inside the column has completely drained. |
3 × 500 μL of buffer |
|
11 |
Combine all effluents into the negative fraction; remove the separation column from the magnetic field and place it over the collection tube. |
— |
|
12 |
Add 1 mL of buffer to the column, and quickly and firmly push the accompanying plunger to elute the magnetically labeled positive cells. Note:For higher purity, use a new column and repeat the separation once. |
Collect the target cells. |
With LSeparation Columnas an example.
Steps |
Operating method |
Dosage / Time |
|
Magnetic labeling |
1 |
Count the total number of cells |
— |
2 |
Centrifuge the cell suspension at 400×g for 7 minutes, and completely discard the supernatant. |
400×g, 7 min |
|
3 |
Resuspend every 1×10⁷ cells in 80 μL of buffer. Note:Adjust the volume of the buffer proportionally according to the sample volume. |
Resuspend the cells. |
|
4 |
Add 20 μL of CD4 NanoBeads per 1×10⁷ cells. Note:When the cell quantity increases, increase the volumes of all reagents proportionally at the same time. |
Add 20 μL per 1×10⁷ cells. |
|
5 |
Mix thoroughly and incubate in the dark at 2–8°C for 15 minutes. |
Incubate for 15 minutes. |
|
6 |
Wash every 1×10⁷ cells with 1 mL of buffer, centrifuge at 400×g for 7 minutes, and completely discard the supernatant. |
Add 1 mL to 1×10⁷ cells |
|
7 |
Resuspend up to 1×10 in 500 μL of buffer8Cells |
Resuspend cells |
|
Magnetic separation |
8 |
Place the L-shaped separation column into the magnetic field of the corresponding magnetic separator, and rinse the column with 3 mL of buffer. |
Rinse the separation column |
9 |
Load the cell suspension onto the separation column and collect the effluent (unlabeled cells). |
— |
|
10 |
Wash the column with buffer three times, each time using 3 mL; add the next wash only after the liquid inside the column has completely drained. |
3 × 3 mL of buffer |
|
11 |
Combine all effluents into the negative fraction; remove the separation column from the magnetic field and place it over the collection tube. |
— |
|
12 |
Add 5 mL of buffer to the column, and use the accompanying plunger to quickly and firmly push, eluting the magnetically labeled positive cells. Note:For higher purity, repeat the separation once using a new column. |
Collect the target cells. |
Picture
Picture
Validation Data