Using the CD11c Nanobeads Kit, mouse S(L) separation columns, and a cell sorter, CD11c-positive cells were isolated from a single-cell suspension of mouse spleen. Subsequently, fluorescent staining was performed with APC Armenian Hamster Anti-Mouse CD11c Antibody (N418) (STD Cat: S0B5085) and FITC Rat Anti-Mouse I-A/I-E Antibody (M5/114.15.2) (STD Cat: S0B1661), and the live cell population was gated for analysis.
Product Details
Product Details
Product Specification
| Format | Dextran-coated iron oxide nanomagnetic beads conjugated with an anti-mouse CD11c monoclonal antibody, in a PBS buffer system containing BSA and Poloxamer 188. |
| Capacity |
1 mL magnetic beads: suitable for 1×10nineTotal cell count: up to 100 sorting runs can be performed. 2 mL magnetic beads: suitable for a total cell count of 2 × 10⁹, enabling up to 200 sorting runs. |
| Principle of Separation | CD11c⁺ cells are magnetically labeled using CD11c Nanobeads, mouse. The cell suspension is then loaded into a separation column placed within the sorter's magnetic field. The magnetically labeled CD11c⁺ cells remain retained in the column, while the unlabeled cells elute; this fraction constitutes the negative fraction after depletion of CD11c⁺ cells. After removing the separation column from the magnetic field, the magnetically captured CD11c⁺ cells can be eluted, yielding the positive sorted fraction. |
| Applications in cell sorting | Isolate or deplete CD11c+ cells from a single-cell suspension of mouse spleen. |
| Reactivity | Mouse |
| Magnetic Bead Size | 20 nm |
| Separation Method | Column-Based |
| Selection Strategy | Positive Selection |
| Stability & Storage | Store protected from light at 2–8°C; do not freeze. |
Background
CD11c Nanobeads are specifically designed for the isolation of CD11c-positive cells (such as dendritic cells, DCs) from single-cell suspensions derived from murine lymphoid and non-lymphoid tissues. Unlike human cells, all known subsets of dendritic cells in mice express CD11c, and certain tissue-resident macrophage subsets also carry this marker. By using these CD11c magnetic beads, you can replace the traditionally laborious and complex steps of dendritic cell isolation with a simple and rapid positive-selection protocol.
Protocol
Note: This kit does not include sorting buffer; please prepare it yourself. The corresponding Stater product number isS0D3018
Taking S Separation Column as an example
Steps |
Operating method |
Dosage / Time |
|
Magnetic labeling |
1 |
Take the mouse spleen, grind it on a 40 μm sterile filter to prepare a single-cell suspension of the spleen; after red blood cell lysis, proceed with cell counting Note:It is recommended to count cells after staining with AO/PI. |
— |
2 |
Centrifuge the cell suspension at 400×g for 7 minutes, and completely discard the supernatant. |
400×g, 7 min |
|
3 |
Resuspend every 1×10⁷ cells in 90 μL of buffer. Note:Adjust the volume of the buffer proportionally according to the sample volume. |
Resuspend the cells |
|
4 |
Add 10 μL of CD11c Nanobeads per 1×10⁷ cells Note:When the cell quantity increases, increase the volume of all reagents proportionally at the same time. |
1 × 10⁷ cells plus 10 μL |
|
5 |
Mix thoroughly, incubate in the dark at 2–8°C for 15 minutes |
Incubate for 15 min |
|
6 |
Add 1 mL of buffer to every 1 × 10⁷ cells for washing, centrifuge at 400 × g for 7 minutes, and completely discard the supernatant |
1 × 10⁷ cells plus 1 mL |
|
7 |
Resuspend up to 1 × 10 in 500 μL of buffer8Cells |
Resuspend cells |
|
Magnetic separation |
8 |
Place the S-type separation column into the magnetic field of the corresponding magnetic separator, and rinse the column with 500 μL of buffer |
Rinse the separation column |
9 |
Load the cell suspension onto the separation column, and collect the effluent (unlabeled cells) |
— |
|
10 |
Wash the column with buffer three times, 500 μL each time, and add the next wash only after the liquid inside the column has completely drained. |
Three times 500 μL of buffer |
|
11 |
Combine all effluent fractions into the negative fraction; remove the sorting column from the magnetic field and place it on the collection tube. |
— |
|
12 |
Add 1 mL of buffer to the column, then quickly and firmly push with the accompanying plunger to elute the magnetically labeled positive cells. Note:For higher purity, use a new column and repeat the separation once. |
Collect the target cells. |
Taking the L Separation Column as an example.
Steps |
Operating procedure |
Dosage / Time |
|
Magnetic labeling |
1 |
Count the total number of cells: take the mouse spleen, grind it on a 40 μm sterile filter to prepare a single-cell suspension of the spleen; after red blood cell lysis, proceed with cell counting. Note:It is recommended to count cells after staining with AO/PI. |
— |
2 |
Centrifuge the cell suspension at 400×g for 7 minutes, and completely discard the supernatant. |
400×g, 7 min |
|
3 |
Resuspend every 1 × 10⁷ cells in 90 μL of buffer. Note:Adjust the volume of buffer proportionally according to the sample volume. |
Resuspend cells |
|
4 |
Add 10 μL CD11c Nanobeads per 1×10⁷ cells Note:When the cell number increases, proportionally increase the volume of all reagents accordingly |
Add 10 μL per 1×10⁷ cells |
|
5 |
Mix thoroughly and incubate in the dark at 2–8℃ for 15 minutes |
Incubate for 15 min |
|
6 |
Wash with 1 mL of buffer per 1×10⁷ cells, centrifuge at 400×g for 7 minutes, and completely discard the supernatant. |
Add 1 mL per 1×10⁷ cells |
|
7 |
Resuspend up to 1×10 in 500 μL of buffer8Cells |
Resuspend cells |
|
Magnetic separation |
8 |
Place the L-shaped separation column into the magnetic field of the corresponding magnetic separator, and rinse the column with 3 mL of buffer. |
Rinse the separation column |
9 |
Load the cell suspension onto the separation column and collect the flow-through (unlabeled cells). |
— |
|
10 |
Wash the column with buffer three times, 3 mL each time, and add the next wash only after the liquid in the column has completely drained. |
3 × 3 mL of buffer |
|
11 |
Combine all eluates into the negative fraction; remove the separation column from the magnetic field and place it over a collection tube. |
— |
|
12 |
Add 5 mL of buffer to the column, then quickly and firmly push down with the provided plunger to elute the magnetically labeled positive cells. Note:For higher purity, use a new column and repeat the separation once. |
Collect the target cells. |