Skip to product information
1 of 1

UniOne®TR-FRET Human HBS1L/CRBN Ternary Binding Kit

UniOne®TR-FRET Human HBS1L/CRBN Ternary Binding Kit

Catalog Number: UA086167 Brand: UA BIOSCIENCE
Price:
Regular price $730 USD
Regular price Sale price $730 USD
Size:

For shipping services or bulk orders, you may request a quotation.
Secure checkout with
View full details

Product Details

Product Specification


Host Human
Stability & Storage

-80℃

Background

The kit is based on homogeneous time-resolved fluorescence technology (TR-FRET) technology,which is used to assess the molecular glue-mediated interaction between the HBS1L and CRBN. This method provides a high-throughput approach to detect the small molecules capable of mediating the interaction between the HBS1L and CRBN simply and rapidly.

As shown in the figure below, the interaction between HBS1L and CRBN was detected by an Tb-labeled anti-Tag1 antibody (TR-FRET donor) and an Ac-labeled SA (TR-FRET receptor). Since the molecular adhesive TNG961 mediates the interaction between HBS1L and CRBN, the donor antibody is in close proximity to the receptor. Excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the receptor, resulting in specific emission of a signal at a wavelength of 665 nm from the receptor. This specific signal is proportional to the degree of interaction between TNG961, HBS1L and CRBN. This homogeneous assay is simple to perform and requires no washing steps.

Components

Composition

concentration

100T

500T

2500T

10000T

Storage

Tag1-HBS1L protein

100×

5μL

20μL

100μL

400μL

-80℃

Tag2-CRBN protein

100×

5μL

20μL

100μL

400μL

-80℃

TNG961

200μM

5μL

10μL

50μL

200μL

-80℃

Anti-Tag1 Tb antibody

200×

3μL

13μL

63μL

250μL

-80℃

SA Ac

12.5×

40μL

200μL

1000μL

4mL

-80℃

Detection buffer

1×

4mL

20mL

100mL

400mL

-80℃


Note: Aliquot into appropriate volumes, store at the recommended temperature and avoid repeated freeze-thaw cycle.

Protocol

【Process and Operations】

1、Reagent Preparation

1.1 Compositions equilibration

Before use, dissolve all reagents at room temperature (allow at least 30 minutes for temperature equilibration). For the 384-well plate assay, use 20 μL of reaction mixture (the reagent quantities are listed in the table below). Calculate the required volume prior to preparation accordingly. The following preparation steps are provided for reference only, using a 500-well plate as an example.

Table 1. Reagent Preparation

Composition

Configuration

μL/well

Tag1-HBS1L protein

Take 20 μL of the 100× Tag1-HBS1L protein stock solution, add 1.98 mL of 1× Detection buffer to dilute it to 1× concentration, and mix thoroughly for later use.

4

Tag2-CRBN protein

Take 20 μL of 100× Tag2-CRBN protein, add it to 1.98 mL of 1× Detection buffer to dilute to 1× concentration, and mix thoroughly for later use.

4

Antibody Mix

Take 12.5 μL of the 200× Anti-Tag1 Tb antibody , add 2487.5 μL of 1× Detection buffer to dilute to 2.5 mL, and mix thoroughly; take 200 μL of the 12.5× SA Ac, add 2300 μL of 1× Detection buffer to dilute to 2.5 mL, and mix thoroughly; combine the two solutions in a 1:1 ratio to obtain the Antibody Mix.

10


1.2 Gradient dilution of the sample

TNG961 as an example, the dilution solution is 1× Detection buffer. To minimize interference from matrix effects, it is recommended to use a solution with the same matrix composition as the sample being tested; additionally, the sample concentration should be adjusted according to its actual situation.

Table 2. TNG961 gradient dilution(Adjust according to the actual situation)

TNG961 final concentration(nM)

TNG961 preparation concentration(nM)

Dilution

①

200

2000

1μL 200 μM TNG961 +99μL 1× Detection buffer

②

100

1000

30μL ① +30μL 1× Detection buffer

③

50

500

30μL ② +30μL 1× Detection buffer

④

25

250

30μL ③ +30μL 1× Detection buffer

⑤

12.5

125

30μL ④ +30μL 1× Detection buffer

⑥

6.25

62.5

30μL ⑤ +30μL 1× Detection buffer

⑦

3.125

31.25

30μL ⑥ +30μL 1× Detection buffer

⑧

1.563

15.63

30μL ⑦+30μL 1× Detection buffer

⑨

0.781

7.81

30μL ⑧+30μL 1× Detection buffer

⑩

0.391

3.91

30μL ⑨+30μL 1× Detection buffer

⑪

0.195

1.95

30μL ⑩+30μL 1× Detection buffer

Blank

0

0

30μL 1× Detection buffer


2、Sample and control

2.1 Sample:Add 4 μL of Tag1-HBS1L protein working solution, 4 μL of Tag2-CRBN protein working solution, 2 μL of the gradient-diluted sample , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

2.2 TNG961 : 4 μL of Tag1-HBS1L protein working solution, 4 μL of Tag2-CRBN protein working solution, 2 μL of gradient-diluted TNG961 , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

2.3 Blank:4 μL of Tag1-HBS1L protein working solution, 4 μL of Tag2-CRBN protein working solution, 2 μL of Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

2.4 Negative control: 10μL Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.

After adding all samples, centrifuge, seal with a cover membrane, and incubate at room temperature for 1 hour.

Table 3. Sample and control spotting process

TNG961

Sample

Blank

Negative control (NC)

2μL

gradient-diluted TNG961

2μL

gradient-diluted sample

2μL

1× Detection buffer

10μL 1× Detection buffer

and 10μL Antibody Mix

4μL Tag1-HBS1L protein

4μL Tag2-CRBN protein

10μL Antibody Mix

Seal the plate wells with a sealing film and incubate at room temperature for 1hours.


3、Read Data

The detection was performed on a TR-FRET microplate reader. The excitation wavelength was 320/340 nm, and the emission wavelengths at 620 nm and 665 nm were detected.

【DATA REDUCTION 】

1) Ratio:

Ratio = (665/620) ×10000

2) Net signal:

Net signal = (Std-NC)/NC×100

Std:the ratio of sample and control

NC: the ratio of negative control

3) CV(%):

CV(%)= Standard Deviation/Mean Ratio × 100%

【Data Example】

The following data cannot replace experimental results obtained in experiments; they are provided solely for illustrative purposes, and outcomes may vary depending on the plate reader used.

3Note: Recommended microplate

(384-well plate, white, shallow wells).