Product Details
Product Details
Product Specification
| Host | Human |
| Stability & Storage | -80℃ |
Background
The kit is based on homogeneous time-resolved fluorescence technology (TR-FRET) technology,which is used to assess the molecular glue-mediated interaction between the HBS1L and CRBN. This method provides a high-throughput approach to detect the small molecules capable of mediating the interaction between the HBS1L and CRBN simply and rapidly.
As shown in the figure below, the interaction between HBS1L and CRBN was detected by an Tb-labeled anti-Tag1 antibody (TR-FRET donor) and an Ac-labeled SA (TR-FRET receptor). Since the molecular adhesive TNG961 mediates the interaction between HBS1L and CRBN, the donor antibody is in close proximity to the receptor. Excitation of the donor antibody triggers fluorescence resonance energy transfer (FRET) to the receptor, resulting in specific emission of a signal at a wavelength of 665 nm from the receptor. This specific signal is proportional to the degree of interaction between TNG961, HBS1L and CRBN. This homogeneous assay is simple to perform and requires no washing steps.

Components
Composition |
concentration |
100T |
500T |
2500T |
10000T |
Storage |
Tag1-HBS1L protein |
100× |
5μL |
20μL |
100μL |
400μL |
-80℃ |
Tag2-CRBN protein |
100× |
5μL |
20μL |
100μL |
400μL |
-80℃ |
TNG961 |
200μM |
5μL |
10μL |
50μL |
200μL |
-80℃ |
Anti-Tag1 Tb antibody |
200× |
3μL |
13μL |
63μL |
250μL |
-80℃ |
SA Ac |
12.5× |
40μL |
200μL |
1000μL |
4mL |
-80℃ |
Detection buffer |
1× |
4mL |
20mL |
100mL |
400mL |
-80℃ |
Note: Aliquot into appropriate volumes, store at the recommended temperature and avoid repeated freeze-thaw cycle.
Protocol
【Process and Operations】
1、Reagent Preparation
1.1 Compositions equilibration
Before use, dissolve all reagents at room temperature (allow at least 30 minutes for temperature equilibration). For the 384-well plate assay, use 20 μL of reaction mixture (the reagent quantities are listed in the table below). Calculate the required volume prior to preparation accordingly. The following preparation steps are provided for reference only, using a 500-well plate as an example.
Table 1. Reagent Preparation
Composition |
Configuration |
μL/well |
Tag1-HBS1L protein |
Take 20 μL of the 100× Tag1-HBS1L protein stock solution, add 1.98 mL of 1× Detection buffer to dilute it to 1× concentration, and mix thoroughly for later use. |
4 |
Tag2-CRBN protein |
Take 20 μL of 100× Tag2-CRBN protein, add it to 1.98 mL of 1× Detection buffer to dilute to 1× concentration, and mix thoroughly for later use. |
4 |
Antibody Mix |
Take 12.5 μL of the 200× Anti-Tag1 Tb antibody , add 2487.5 μL of 1× Detection buffer to dilute to 2.5 mL, and mix thoroughly; take 200 μL of the 12.5× SA Ac, add 2300 μL of 1× Detection buffer to dilute to 2.5 mL, and mix thoroughly; combine the two solutions in a 1:1 ratio to obtain the Antibody Mix. |
10 |
1.2 Gradient dilution of the sample
TNG961 as an example, the dilution solution is 1× Detection buffer. To minimize interference from matrix effects, it is recommended to use a solution with the same matrix composition as the sample being tested; additionally, the sample concentration should be adjusted according to its actual situation.
Table 2. TNG961 gradient dilution(Adjust according to the actual situation)
TNG961 final concentration(nM) |
TNG961 preparation concentration(nM) |
Dilution |
|
① |
200 |
2000 |
1μL 200 μM TNG961 +99μL 1× Detection buffer |
② |
100 |
1000 |
30μL ① +30μL 1× Detection buffer |
③ |
50 |
500 |
30μL ② +30μL 1× Detection buffer |
④ |
25 |
250 |
30μL ③ +30μL 1× Detection buffer |
⑤ |
12.5 |
125 |
30μL ④ +30μL 1× Detection buffer |
⑥ |
6.25 |
62.5 |
30μL ⑤ +30μL 1× Detection buffer |
⑦ |
3.125 |
31.25 |
30μL ⑥ +30μL 1× Detection buffer |
⑧ |
1.563 |
15.63 |
30μL ⑦+30μL 1× Detection buffer |
⑨ |
0.781 |
7.81 |
30μL ⑧+30μL 1× Detection buffer |
⑩ |
0.391 |
3.91 |
30μL ⑨+30μL 1× Detection buffer |
⑪ |
0.195 |
1.95 |
30μL ⑩+30μL 1× Detection buffer |
Blank |
0 |
0 |
30μL 1× Detection buffer |
2、Sample and control
2.1 Sample:Add 4 μL of Tag1-HBS1L protein working solution, 4 μL of Tag2-CRBN protein working solution, 2 μL of the gradient-diluted sample , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
2.2 TNG961 : 4 μL of Tag1-HBS1L protein working solution, 4 μL of Tag2-CRBN protein working solution, 2 μL of gradient-diluted TNG961 , and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
2.3 Blank:4 μL of Tag1-HBS1L protein working solution, 4 μL of Tag2-CRBN protein working solution, 2 μL of Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
2.4 Negative control: 10μL Detection buffer, and 10 μL of the mixed Antibody Mix sequentially into the 384-well plate.
After adding all samples, centrifuge, seal with a cover membrane, and incubate at room temperature for 1 hour.
Table 3. Sample and control spotting process
TNG961 |
Sample |
Blank |
Negative control (NC) |
|
2μL gradient-diluted TNG961 |
2μL gradient-diluted sample |
2μL 1× Detection buffer |
10μL 1× Detection buffer and 10μL Antibody Mix |
4μL Tag1-HBS1L protein | |||
4μL Tag2-CRBN protein | |||
10μL Antibody Mix | |||
Seal the plate wells with a sealing film and incubate at room temperature for 1hours. | |||
3、Read Data
The detection was performed on a TR-FRET microplate reader. The excitation wavelength was 320/340 nm, and the emission wavelengths at 620 nm and 665 nm were detected.
【DATA REDUCTION 】
1) Ratio:
Ratio = (665/620) ×10000
2) Net signal:
Net signal = (Std-NC)/NC×100
Std:the ratio of sample and control
NC: the ratio of negative control
3) CV(%):
CV(%)= Standard Deviation/Mean Ratio × 100%
【Data Example】
The following data cannot replace experimental results obtained in experiments; they are provided solely for illustrative purposes, and outcomes may vary depending on the plate reader used.

3Note: Recommended microplate
(384-well plate, white, shallow wells).