Product Details
Product Details
Product Specification
| protein | Anti-PEG IgG | ||||||||||||||||||||||||||||||||||||
| Usage |
1. Specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to relevant literature. 2. Unable to detect containing NaN3 Samples, due to NaN3 Inhibition of horseradish peroxidase (HRP) activity. Operation steps 1. Dilution of standard substances: This kit provides one original standard substance, and users can dilute it in a small test tube according to the following chart Interpretation.
2. Sample addition: Set up blank wells (no sample and enzyme labeled reagent are added to the blank control wells, and the other steps are the same), standard wells and sample wells to be tested respectively. 3. Incubation: After plate sealing with plate sealing film 37℃ Incubation 30 Minutes. 4. Solution preparation: will 30 Distilled water for double concentrated washing liquid 30 Time dilution for use 5. Washing: Carefully remove the sealing film, discard the liquid, spin dry, fill each well with washing liquid, and let stand 30 Discard it in seconds and repeat it 5 Times, pat dry. 6. Enzyme addition: enzyme labeled reagent is added to each well 50μl, except for blank holes. 7. Incubation: Same procedure 3. 8. Washing: Same operation 5. 9. Color development: Add color developer to each well first A50μl And then adding a color developer B50μl, gently shake and mix evenly, 37℃ Color development protected from light 10 minute. 10. Stop: Add stop solution per well 50μl, terminate the reaction (blue immediately turns yellow at this time). 11. Measurement: Zero adjustment with blank holes, 450nm The absorbance of each well was measured sequentially by wavelength (OD Value). calculate Taking the concentration of the standard as the abscissa, OD The value is the ordinate, draw a standard curve on the coordinate paper, and according to the sample OD The corresponding concentration is found out from the standard curve; Multiply by the dilution factor; |
||||||||||||||||||||||||||||||||||||
| Sensitivity | 10pg/ml | ||||||||||||||||||||||||||||||||||||
| Species Reactivity | Monkey | ||||||||||||||||||||||||||||||||||||
| Theory | This kit uses double antigen sandwich method to determine the level of monkey anti-polyethylene glycol IgG antibody (PEG-IgG) in specimens. Coating the microplate with the purified antigen to prepare the solid phase antigen, adding anti-polyethylene glycol IgG antibody (PEG-IgG) to the coated microwells sequentially, and then combining with the HRP-labeled antigen to form an antigen-antibody-enzyme-labeled antigen complex, which is thoroughly washed and colored by adding substrate TMB. TMB is converted to blue under the catalysis of HRP enzyme and to the final yellow under the action of acid. There was a positive correlation between the depth of color and the anti-polyethylene glycol IgG antibody (PEG-IgG) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of monkey anti-polyethylene glycol IgG antibody (PEG-IgG) in the sample was calculated by the standard curve. | ||||||||||||||||||||||||||||||||||||
| Source | Monkey | ||||||||||||||||||||||||||||||||||||
| Synonym | Monkey anti-polyethylene glycol IgG antibody (PEG-IgG) enzyme-linked immunosorbent kit | ||||||||||||||||||||||||||||||||||||
| Detection Type | It is used to determine the content of anti-polyethylene glycol IgG antibody (PEG-IgG) in monkey serum, plasma and related fluid samples. | ||||||||||||||||||||||||||||||||||||
| Composition |
|
||||||||||||||||||||||||||||||||||||
| General Notes |
1. The kit should be taken out of the refrigerated environment and balanced at room temperature for 1 hour before it can be used. If the enzyme-labeled coated plate is not used up after opening, the strips should be stored in a sealed bag. 2. Crystals may precipitate in the concentrated washing liquid. When diluting, it can be heated in a water bath to help dissolve, and the results will not be affected during washing. 3. A sampler should be used in each step of sampling, and its accuracy should be checked frequently to avoid test errors. It is best to control the sample addition time within 5 minutes. If the number of specimens is large, it is recommended to use a row gun to add samples. 4. Please make a standard curve at the same time of each measurement, preferably a double hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with the sample diluent for a certain multiple (n times) before measuring, and please finally multiply it by the total dilution multiple (× n × 5) when calculating. 5. The sealing film is only for one-time use to avoid cross-contamination. 6. Please keep the substrate away from light. 7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader. 8. All samples, washing solutions and various wastes should be treated as infectious agents. 9. Components of different batch numbers of this reagent shall not be mixed. |
||||||||||||||||||||||||||||||||||||
| Storage Temp. | Unopened kit, sealed storage at 2-8 ℃, shelf life 6 months | ||||||||||||||||||||||||||||||||||||
| Test Range | 40pg/ml –2200pg/ml |