Abbkine Homogeneous Detection Solutions

Abbkine Homogeneous Detection Solutions

TR-FRET(Time-Resolved Fluorescence Resonance Energy Transfer

Time-Resolved Fluorescence Resonance Energy Transfer (TR-FRET) is a biophysical technique that combines Fluorescence Resonance Energy Transfer (FRET) with Time-Resolved Fluorescence (TRF).
  • Fluorescence Resonance Energy Transfer (FRET): When a fluorescent molecule (donor) absorbs light energy, it can non-radiatively transfer this excited energy to another molecule (acceptor), provided that the acceptor is in close proximity to the donor (typically within a range of 1-10 nanometers), and there is an overlap between the donor's emission spectrum and the acceptor's excitation spectrum.
  • Time-Resolved Fluorescence (TRF): By measuring the decay of fluorescence after the excitation light source has been stopped, it is possible to distinguish between short-lived background fluorescence and long-lived signal fluorescence. TR-FRET typically employs chelates of lanthanide elements (such as europium or terbium) as long-lived donor fluorophores.
  • Energy Transfer Process: In TR-FRET, after the donor is excited, if it is in close enough proximity to the acceptor, energy is transferred to the acceptor, causing it to emit fluorescence as well. By detecting the fluorescence after a delay following excitation, it is possible to effectively reduce background interference.

 

Technical Advantages
  • Simple Operation: No complex washing steps are required, making it easy to automate.
  • Wide Linear Range: Capable of detecting both high and low concentrations of samples with a broad linear detection range.
  • Rapid Detection: Detection can be completed in as little as 1 hour, significantly improving experimental efficiency.
  • Low Background Signal: The long fluorescence lifetime of lanthanide elements allows for delayed detection after excitation, eliminating interference from short-lived fluorescence.

 

TR-FRET Product Recommendation List

Product Number Product Name Application

abs560002

Human Total IgG Kit (Assay Pro)

Detects Human IgG antibodies in cell culture supernatants

abs560011

Human IgG Sandwich Assay Kit

Detects the concentration of human IgG antibodies or hFc-tagged proteins in cell culture supernatants

abs560013

TR-FRET Kinase-TK Assay Kit

Activity detection and inhibitor screening of various kinases

abs560003

Human KRAS WT&cRAF Binding Kit

Rapidly detects small molecule inhibitors that interact with KRAS-cRAF

abs560004

Human KRAS G12C&cRAF Binding Kit

abs560012

Human DDB1-CRBN&GSPT1 Binding Kit

Detects small molecules that interact with the DDB1/CRBN complex and GSPT1

abs560014

Human TNF-α/TNFR1 Binding Kit

Determines the interaction between TNF-α and TNFR1

abs560019

Human IL4/IL4R Binding Kit

Determines the interaction between cytokine interleukins and their receptors, as well as their inhibitors and antibody (blockers)

abs560040

Human IL10A/IL10RA Binding Kit

abs560042

Human BCL-XL/CRBN PROTAC Binding Kit

Detects small molecules that interact with the DDB1/CRBN complex and BCL-XL

abs560044

Human BCL-XL/VHL PROTAC Binding Kit

Detects small molecules that interact with the VHL complex and BCL-XL

abs560016

Human BRD4/CRBN PROTAC Binding Kit

Detects small molecules that interact with the DDB1/CRBN complex and BRD4

abs560043

Human Epigeneous Bromodomain Binding Kit

Determines the interaction between BRD4 and [ILYS(5,8,12,16)AC] H4(1-21) peptide, as well as their inhibitors and antibody (blockers)

PD1/PD-L1 and more TR-FRET products...

 

Data Example(abs560012  an example)

 

 

The above data cannot replace the data obtained from experiments and are provided only as examples. Results may vary depending on the TR-FRET compatible instrument used.

Homogeneous Chemiluminescent Assay (HICA)

HICA is a chemiluminescent technology based on nanoparticles. It detects interactions between biomolecules via energy transfer between two types of microspheres (donor and acceptor microspheres). The principle is as follows:

  • Donor Microspheres: Coated with a photosensitizer (e.g., phthalocyanine dye). When excited by 680 nm red light, they convert oxygen molecules in the environment into high-energy singlet oxygen.
  • Acceptor Microspheres: Coated with a luminescent agent (e.g., a dimethylthiophene derivative) and a rare-earth chelate (e.g., europium). When singlet oxygen diffuses to these microspheres, it excites the luminescent agent to produce fluorescence at around 610 nm.
  • Energy Transfer: When the two types of microspheres are brought within 200 nm of each other due to biomolecular interactions (e.g., antigen-antibody binding), singlet oxygen can transfer from the donor to the acceptor microspheres, producing a chemiluminescent signal.

 

 

Technical Advantages

  • High Sensitivity: Energy transfer from singlet oxygen enables detection limits as low as the femtomolar range.
  • Low Background: The detection wavelength is longer than the excitation wavelength, reducing interference from impurities.
  • Easy Operation: No washing steps are required, making it suitable for automated and portable detection.
  • Miniaturization: Ideal for developing miniaturized, high-throughput detection platforms.

HICA Product Recommendation List

Product Number Product Name Application

abs560027

Human IL-10 Kit (HICA)

500T/2000T/10000T

abs560028

Human IL-17A Kit (HICA)

500T/2000T/10000T

abs560023

Human IL-2R Kit (HICA)

500T/2000T/10000T

abs560034

Human TNF-α Kit (HICA)

500T/2000T/10000T

abs560036

Human TNF-β Kit (HICA)

500T/2000T/10000T

abs560033

Mouse IFN-γ Kit (HICA)

500T/2000T/10000T

abs560041

HICA Human IgG Kit

200T/500T/5000T

IL-5\IL-12p70 and more related indicators...

 

Data Example(abs560034  an example)

 

Lower Detection Limit: 0.2–3 pg/mL for different matrices

Dynamic Range: 0–100,000 pg/mL

Linear Range: 0.39–10,000 pg/mL

High Concentration CV Value: 1.5–5%

Recovery Rate: 90–110%

Cross-Interference Rate: 0% for five tested samples

 

Bioluminescence

Bioluminescence is a type of chemiluminescence where light signals are generated within living organisms via chemical reactions without the need for external light stimulation. This process typically involves a chemical reaction between an enzyme (luciferase) and its substrate (luciferin).
Using firefly luciferase as an example, the process is as follows:
  • Enzyme-Substrate Binding: Firefly luciferase binds to its substrate luciferin. The enzyme then combines with ATP (adenosine triphosphate) and luciferin to form an enzyme-substrate complex.
  • Oxidation Reaction: Catalyzed by luciferase, luciferin reacts with oxygen to form oxyluciferin. During this reaction, chemical energy is converted into light energy, releasing a photon.
  • Light Production: The emitted photon produces visible light, typically a yellow-green light with a wavelength of around 560 nm. This light signal can be detected by devices such as luminometers or imaging systems.

 

 

Bioluminescence Detection Product Recommendation List

Catalog Number Product Name Specification Application

abs580117

ATP Microplate Assay Kit

96T

Assess cell proliferation, damage, activation, and intracellular granule release

abs50065

2D Luminescent Cell Viability Assay

50mL×2

Detect bioactive factors, screen anti-tumor drugs, and perform cell proliferation and toxicity tests

abs50059

2D/3D/Organoid ATP Viability Assay Kit

10mL

Assess cell numbers in organoids

abs50057

3D Luminescent Cell Viability Assay

50mL×2

Detect bioactive factors in 3D cell cultures, screen anti-tumor drugs, and perform cell proliferation and toxicity tests

abs580122

ATP Synthase Microplate Assay Kit

96T

Detect ATP synthase activity, study energy metabolism, and screen drugs

abs60341

Dual-Luciferase Reporter Assay Kit

100T

Assess the transcriptional regulation of target genes by drug treatment

abs60343

Secreted Luciferase Reporter Assay Kit

200T

Detect reporter genes

abs60616

NLuc Luciferase Reporter Assay Kit

500T

Analyze reporter genes

abs60344

One-Step Firefly Luciferase Reporter Assay Kit

50T

Gene regulation and drug screening

abs60342

Firefly Luciferase Reporter Assay Kit

50T

Detect reporter genes

abs50131

ATP/ADP Ratio Chemiluminescent Assay Kit

96T

Measure the ATP/ADP ratio in cell samples to analyze cell status

abs42075819

D-Luciferin Potassium Salt

25mg

In vitro bioluminescent detection and in vivo imaging analysis

abs42017259

D-Luciferin Sodium Salt

100mg

In vitro bioluminescent detection and in vivo imaging analysis

 

Data Example(abs42075819  an example)

 

 

Detection Consumables

Catalog Number Product Name Specification

abs7311

Microplate (384-well, white, flat-bottom)

40plates/box

abs7308

Microplate (96-well, white, flat-bottom)

50plates/box

 

Absin provides antibodies, proteins, ELISA kits, cell culture, detection kits, and other research reagents. If you have any product needs, please contact us.

Absin Bioscience Inc.
Email: worldwide@absin.cn